MTT MS3709 User Manual Download Page 2

  User's Manual 

MS3709 

Slim Plug-In Pulse Shaper with Isolated Single/Dual Output 

 

Rev. 1.50 

 
 

 

 
On Wiring: 

  Connections to the instrument should be made to the terminal 

block. For assignment of the terminals, refer to section 6. The 
recommended screwing torque is 0.8 to 1.0 Nm. 

  For lead wires, use a highly flexible stranded conductor. The 

recommended nominal cross-section of the lead wire conductor 
is 0.5 to 2.0 mm

2

  The connection of the lead wire to the terminal block should be 

made with the insulated crimp terminal attached to the end of the 
wire. Without the insulation, short circuit or electric shock may 
occur. The recommended thickness of the crimp terminal is 0.7 
to 1.0 mm. 
Note that only up to two (2) crimp terminals can be connected to 
one (1) terminal screw. In this case, the thickness of the crimp 
terminal should be not greater than 0.8 mm.

 

 

φ3.7

6.8

 m

ax

.

3.4 max.

4.6 min.

 

 

To Avoid Erroneous Measurements: 

  In order to reduce the influence of noise, the input/output wire 

and power supply wire should not be used in a same bundle or 
same conduit. They should be installed separately with a 
minimum distance of 200 mm. 

 Avoid wiring the signal lines in the vicinity of equipment 

generating magnetic fields or electromagnetic waves, such as 
electric motors and large-scale transformers. If inevitable, 
anti-noise measures such as employment of shielded wires are 
indispensable. 

  At least 30 minutes of warm-up is required prior to operation. 

  Any sensor or equipment to be connected to the instrument 

should be selected in consideration of the input/output 
impedance of the same. (For detailed specifications, refer to 
section 4 or the relevant product specification sheet that can be 
downloaded from our website at https://www.mtt.co.jp.) 

Special Notes for CE Marking:

 

  The instrument is designed and manufactured to conform to the 

following EMC and Low Voltage Directives: 
EMC Directive (2014/30/EU) 
    - Standard conformity: EN61326-1:2013 Class A 
Low Voltage Directive (2014/35/EU) 
    - Standard conformity: IEC61010-1 
                                            EN61010-1:2010/A1:2019 
    - Overvoltage Category: II 
    - Pollution Degree: 2 

  The instrument must be installed in a control panel. 

  The instrument maintains basic insulation between input and 

output, and between output and FG. Prior to installation, check 
that the insulation class of the instrument satisfies your system 
requirements. 

  When the instrument is installed in a control panel, the measures 

to be taken for CE marking conformity may vary with the type of 
devices connected, wiring to the instrument or structure of the 
control panel. Therefore, you should check that the control panel 
as an overall system conforms to the CE marking regulations. 

 

4. About the Product

 

The MS3709 accepts pulse train signals from sensors or other 
devices, shapes these pulses or converts signal levels, and 
provides isolated output signals.

 

 

Features: 

  Pin and socket contacts are gold-plated (0.2

μ

m) to ensure high 

reliability and long-term stability. 

  High dielectric strength of 2,000 VAC between input, [output 1, 

output 2], power, and ground. 

  The power unit can deliver AC power ranging from 85 to 264V 

steplessly without switching to meet varied power requirements. 

  Plug-in type for better maintainability 

  Drop-proof terminal screws for ease and safety of installation 

  Fuse installed in the power line as standard. 

 

Specifications 

 

Input Resistance 

Voltage input: 1M

Ω

 min. with power 

10k

Ω

 min. without power 

Current input: 250

Ω

 (standard for 4-20mA) 

 

Allowable Input 
Voltage 

DC voltage input: 30V DC max., continuous. 
DC current input: 40mA DC max., continuous. 
AC voltage input: 200Vp-p AC max., 
continuous (up to ±100V with reference to 0V). 

 

Input Pulse 
Width 

10µs min. (for both ON and OFF) 

 

Sensor Power 
Supply 

30mA max. (2-wire or 3-wire type) 

 

Allowable Output 
Load 

TTL level (Maximum output: 10mA @ 3.5V) 
Voltage pulse 10V (Maximum output 7mA @ 
±10%) 
Voltage pulse 12V (Maximum output 7mA @ 
±10%) 

 

Maximum Rating  Open collector (Maximum rating: 30V, 100mA)   

Maximum Output 
Frequency 
without Pulse 
Hold Function 

Voltage pulse output. 50kHz 
Open collector output: 20kHz 
(For both of the above, the conditions are as 
follows: input pulse duty ratio 50% and 
standard threshold voltage.) 

 

Output Pulse 
Hold Time 
Accuracy 

Better than ±20% 

 

Insulation 
Resistance 

100M

Ω

 min. (@ 500V DC) between input, 

output 1, output 2, power, and ground. 

 

Dielectric 
Strength 

Input / [Output 1, Output 2] / [Power, Ground]: 
2000V AC for 1 minute (Cutoff current: 0.5mA) 
Power / Ground: 2000V AC for 1 minute (Cutoff 
current: 5mA) 
Output 1 / Output 2: 500V AC for 1 minute 
(Cutoff current: 0.5mA) 

 

Surge Withstand 
Capability 

Tested as per ANSI/IEEE C37.90.1-1989. 

 

Storage 
Temperature 

-10 to 60°C 

 

Installation Position

 

Typical Installation Example

 

Reviews: