MTT MS3700DV User Manual Download Page 2

  User's Manual 

MS3700DV  Slim Plug-In Voltage Divider 

 

Rev. 1.30 

 
 

 

 
On Wiring: 

  Connections to the instrument should be made to the terminal 

block. For assignment of the terminals, refer to section 6. The 
recommended screwing torque is 0.8 to 1.0 Nm. 

  For lead wires, use a highly flexible stranded conductor. The 

recommended nominal cross-section of the lead wire conductor 
is 0.5 to 2.0 mm

2

  The connection of the lead wire to the terminal block should be 

made with the insulated crimp terminal attached to the end of the 
wire. Without the insulation, short circuit or electric shock may 
occur. The recommended thickness of the crimp terminal is 0.7 
to 1.0 mm. 
Note that only up to two (2) crimp terminals can be connected to 
one (1) terminal screw. In this case, the thickness of the crimp 
terminal should be not greater than 0.8 mm. 

 

φ3.7

6.8

 m

ax

.

3.4 max.

4.6 min.

 

 

To Avoid Erroneous Measurements: 

 Avoid wiring the signal lines in the vicinity of equipment 

generating magnetic fields or electromagnetic waves, such as 
electric motors and large-scale transformers. If inevitable, 
anti-noise measures such as employment of shielded wires are 
indispensable. 

  At least 30 minutes of warm-up is required prior to operation. 

  Any sensor or equipment to be connected to the instrument 

should be selected in consideration of the input/output 
impedance of the same. (For detailed specifications, refer to 
section 4 or the relevant product specification sheet that can be 
downloaded from our website at https://www.mtt.co.jp.) 

 

Special Notes for CE Marking:

 

  The instrument is designed and manufactured to conform to the 

following EMC Directive: 
EMC Directive (2014/30/EU) 
    - Standard conformity: EN61326-1:2013 Class A 

  The instrument must be installed in a control panel. 

  When the instrument is installed in a control panel, the measures 

to be taken for CE marking conformity may vary with the type of 
devices connected, wiring to the instrument or structure of the 
control panel. Therefore, you should check that the control panel 
as an overall system conforms to the CE marking regulations. 

 

4. About the Product

 

The MS3700DV divides high DC input voltage.

 

 

Features: 

  Pin and socket contacts are gold-plated (0.2

μ

m) to ensure high 

reliability and long-term stability. 

  Plug-in type for better maintainability 

  Drop-proof terminal screws for ease and safety of installation 

 

Specifications 

 

5. External Dimensions & Terminal Assignments

 

 

Screw hole for wall mounting

Screw hole for
wall mounting

Fixing screw

 

 
 

6. Terminal Connection Diagram 

 

Terminal

No.

 

 
 

Input Resistance 

Approx. 1.2M

Ω

 

 

Allowable Input 
Voltage 

600V DC max., continuous. 

 

Output Resistance  Approx. 2k

 

 

Accuracy Rating 

Better than ±0.2% of span (at 25°C±5°C) 

 

Temperature 
Effect 

Better than ±0.05% of span per 10°C change 
in ambient. 

 

Storage 
Temperature 

-10 to 60°C 

 

Installation Position

 

Typical Installation Example

 

Reviews: