Temposonics
®
R-Series
V
SSI
Operation Manual
I 27 I
Output
Interface
SSI (Synchronous Serial Interface) – differential signal in SSI standard (RS-485 / RS-422)
Data format
Binary or gray
Data length
8…32 bit
Data transmission rate
70 kBaud
7
…1 MBaud, depending on cable length:
Cable length
< 3 m
< 50 m
< 100 m
< 200 m
< 400 m
Baud rate
1 MBd
< 400 kBd
< 300 kBd
< 200 kBd
< 100 kBd
Measured value
Position
Measurement parameters
Resolution: Position
0.1…100 µm (0.0001…0.1 mm)
Update rate
8
Stroke length
25 mm
300 mm
750 mm
1000 mm
2000 mm
6350 mm
Update rate
10 kHz
3.4 kHz
2.7 kHz
2.1 kHz
1.2 kHz
0.4 kHz
Linearity deviation
9
Stroke length
≤ 400 mm
> 400 mm
Linearity deviation ≤ ±40 μm
< ±0.01 % F.S.
Repeatability
< ±0.001 % F.S. (minimum ±2.5 μm) typical
Hysteresis
< 4 µm typical
Temperature coefficient
< 15 ppm / K typical
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
IP67 (connectors correctly fitted)
Shock test
150 g / 11 ms, IEC standard 60068-2-27
Vibration test
30 g / 10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The sensor meets the requirements of the EC directives and is marked with
Magnet movement velocity
Magnet slider: Max. 10 m/s; U-magnet: Any; block magnet: Any
Design / Material
Sensor electronics housing
Aluminum (painted), zinc die cast
Sensor profile
Aluminum
Stroke length
25…6350 mm (1…250 in.)
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawings on page 9
Electrical connection
Connection type
1 × M16 male connector (7 pin)
Operating voltage
+12…30 VDC
±
20 % (9.6…36 VDC)
Power consumption
1.2 W typical
Dielectric strength
500 VDC (DC ground to machine ground)
Polarity protection
Up to −36 VDC
Overvoltage protection
Up to 36 VDC
8. Technical data
7/
With standard one shot of 16 μs
8/
Sensor with standard settings
9/
With position magnet # 252 182
8.1 Technical data Temposonics
®
RP5