R e l i a b l y S e r v i n g a T h i r s t y W o r l d
®
1770 Brackett St., La Verne CA 91750 USA
•
T:
909-629-7301
•
F:
909-629-7380
•
www.mtnproducts.com
•
POU Install
(X) Explained
•
X ranges from 0 to
24
.
0
means turn off SIP
®
mode. Example: If initial POU
installation was completed at
12
noon, entering setup mode and pushing auto
clean button
12
times
(
1
push of the button equals
1
hour)
and then pressing
the “Water” dispense button to lock in setting, the cooler will start Auto SIP
mode at midnight.
•
The system automatically exits setup mode if the water dispense button is not
pressed within
15
seconds of pressing auto clean button. Pressing any other
buttons other than SIP auto clean or water dispense will exit set up mode.