1. Parts

The product consists of a Sciaticalm unit, leg and back straps and 
one AAA battery.

2. Preparation for use

The unit requires 1 x AAA battery (included).

Before use, unscrew the battery cover cap and if fitted remove 

the insulation tab and any packaging from the battery. Re-screw 

the battery cover cap tightly.

Always insert the battery 

carefully, taking care to 

insert in the correct 

orientation. Inside the battery

compartment the terminals are 

identified with a ‘+’ and ‘-’.

4. Fitting the unit

Thread the strap through the slot  
with the fibrous side facing the 
battery compartment.

Slide the unit the length of the 
strap and secure under the tab. 
Place the unit on the point of pain 
and loop the end of the strap 
through the black end buckle.

Use the longer strap for positioning 
on the lower back or lumbar 
region. The unit can be rotated to 
point downwards if necessary.

Use the shorter strap for positioning 
on the back of the leg behind the 
knee. The unit can now be operated 
by pressing the start/stop button. 

Warnings and Safety

Before using the device, please read and understand the following warnings 

to ensure the safe and correct use of the device and to prevent any injury.

• 

  Do not throw or drop the device from a height. The unit should not be 

     used if any physical damage is evident.

   Do not use any chemicals to clean any part of the unit.

•  

 Only to be used by persons over the age of 18 years old.

Medical electrical equipment requires special precautions regarding 
electromagnetic compatibility (EMC) and must be installed and used 
according to the instructions contained in this manual. Portable or mobile 
radio communication equipment may affect medical electrical equipment.

• 

  Do not use the device unless your condition has been diagnosed by a doctor.

• 

  Do not use for conditions other than mechanical back pain and sciatica.

   Ensure that the battery is installed correctly.

•   

The device is designed for use on the leg or lower back (lumbar region); 

     do not use on any other part of the body.

3. Using the unit

In order to optimise the performance of the device, the nozzle on 

the lower side needs to be placed over the sciatic nerve using one 

of the straps provided. This can be either on the lower back or leg. 

It may be necessary to move the device to find the optimum 

position for pain relief.

The strap is then secured in order to hold the device in place while 

not restricting the blood flow by ‘over-tightening’.

The start/stop button on the battery cover is then depressed in 

order to activate the unit. The Sciaticalm unit can be stopped or 

started manually at any time by depressing the start/stop button. 

Do not exceed a 10 minute cycle each time you use the device.

It is recommended that the Sciaticalm unit is used for 30 minutes 

each day, in separate 10 minute treatments. You can use the 

device for less than 3 cycles per day, or for a shorter time. Use the 

device for 3-4 weeks for maximum benefit.

Battery Cover

Strap Slot

Vibration 

Head

•  

 If you feel unwell or experience any discomfort at any time, stop using 

     the device immediately.

• 

  If you notice any reddening of the skin, stop using the device immediately.

• 

  Only apply the device to normal skin. If suffering from a skin condition 

     or new scar tissue is present in the area of application, seek medical 
     advice before use.

•  

 Do not use the device while sleeping.

  

 Do not disassemble, repair or modify the device in any way, as this will 

     invalidate the warranty and may lead to malfunction of the device or an injury.

•  

 Do not immerse the device in water or any other fluid.

Start / Stop 

Button

Press here

Longer strap for

lumbar region

Shorter strap

for back of leg

Fibrous side