Uploading Codes to Puck

Uploading Codes to Intellikeys

PROGRAMMING

Connect MCP to the Puck. The MCP beeps once. Puck LED will be 
flashing.

Plug key(s) into the IntelliKey port(s) with the MTI logo facing down. 
Wait for each key’s LED to turn RED or GREEN.

Press and release the Function button. The MCP beeps once. Wait for 
the second confirmation beep. Puck LED will still be flashing, but no 
sound will come from the alarm. 

IF THE LED IS RED: 

Press the Function button on the MCP. The MCP 

beeps once and each key’s LED should then turn solid green.

IF THE LED IS GREEN: 

The key’s existing code already matches the 

current code in the MCP and no further action is required.

Connect the MCP to a Puck or other power supply (USB power supply or 
PC USB port). The MCP beeps once when power is applied.

Press

Press

The MCP button may need 
to be pressed more than 
once to transfer the code.

The key LED may 
take up to 6 seconds 
to light up.

Summary of Contents for ROGERS FREEDOM MICRO

Page 1: ...P N 063 1581 00 rev B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 3 5 2 4 6 ROGERS The socket outlet shall be installed near the equipment and shall be easily accessible ...

Page 2: ...ease the Function button The MCP beeps once Wait for the second confirmation beep Puck LED will still be flashing but no sound will come from the alarm IF THE LED IS RED Press the Function button on the MCP The MCP beeps once and each key s LED should then turn solid green IF THE LED IS GREEN The key s existing code already matches the current code in the MCP and no further action is required Conn...

Page 3: ... B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 3 2 4 FREEDOM MICRO INSTALLATION GUIDE MTI MTI ARMING THE SYSTEM If the key does not turn green repeat programming steps on the previous page ...

Page 4: ...3 1581 00 rev B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 3 2 1 3 2 4 USER GUIDE Removing Installing the Display Puck Adjusting The Merchandising Angle REMOVAL INSTALLATION ...

Page 5: ...MICRO INSTALLATION GUIDE 5 MTI P N 063 1581 00 rev B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 4 7 2 5 8 3 6 9 REPLACING THE AIR TETHER ...

Page 6: ...EEDOM MICRO INSTALLATION GUIDE 6 MTI P N 063 1581 00 rev B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 4 7 2 5 8 3 6 9 MERCHANDISING ...

Page 7: ...FREEDOM MICRO INSTALLATION GUIDE 7 MTI P N 063 1581 00 rev B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 3 5 2 4 6 PUCK REMOVAL ...

Page 8: ...FREEDOM MICRO INSTALLATION GUIDE 8 MTI P N 063 1581 00 rev B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 3 5 2 4 6 RISER REMOVAL ...

Page 9: ...ATION GUIDE 9 MTI P N 063 1581 00 rev B 2014 MTI All Rights Reserved MTI 1050 NW 229th Avenue Hillsboro OR 97124 T 800 426 6844 www mobiletechinc com MTI 1 3 2 4 FREEDOM MICRO INSTALLATION GUIDE MTI MTI SILENCING THE ALARM ...

Page 10: ...e of alarm due to theft tampering or improperly mounted customer product Insert IntelliKey to silence alarm Fix alarming condition check mounted product Remove IntelliKey Puck LED solid blue Alarm module LEDs are solid red No audible alarm Puck is seated in riser Short circuit in SmartCable or customer product Replace SmartCable If issue is not resolved replace customer product In order to maximiz...

Page 11: ...no warranty for such items USB interconnect cables extension cables SmartCables FlexSensors Membrane Sensors anti skid pads anti rotation brackets VHB adhesive pads X and L brackets CC and DC brackets cable clamps zip ties and installation retrieval and removal tools Unused SmartCables and Secondary Sensors that are demonstrated by Customer to have been faulty upon delivery to Customer will be rep...

Reviews: