background image

6

 MTI P/N 063-00216 rev C ©2021 MTI All Rights Reserved

www.MTIGS.com  |  T:801.653.3807

1

1

2

2

REMOVING THE ENCLOSURE (OR TABLET) MANUALLY

REMOVING THE ENCLOSURE (OR TABLET) VIA RFID

Insert the Red Handle Tool into the security screw hole 
at the side of the RapidDoc

®

 base-disk under the tablet. 

Turn the Red Handle Tool clockwise until resistance is 
felt (about halfway) and hold. 

NOTE: Do not grab the 

tablet until after you twist the Red Handle Tool.

Place the RFID Access Card until the base clicks. 

NOTE: 

Do not grab the tablet until after you hear the click.

While holding the Red Handle Tool, remove the tablet 
using one hand on the bottom left or right hand corner.

Remove the tablet using one hand on the bottom left or 
right hand corner.

-CONTROLLED DOCUMENT-

063-00216

C-0

Status: Approved

ECO-112352

ECO-112352

Summary of Contents for RAPIDDOC

Page 1: ...rvice for replacement Access Card 5 RapidDoc Kiosk C A Cover Minimal Cables C A Cover No Cables Cable Access C A If the Kiosk is not mounted to a counter or table it may fall causing damage to the Kio...

Page 2: ...rmorActive logo Tuck the RFID cable into the void in the base and place the lid on the kiosk base With the lid off of the kiosk base place the Cable Access Cover into the opening from the inside Slide...

Page 3: ...in the desired location See Page 9 for a Mounting Plate drill template Lock the kiosk into place by rotating it counter clockwise on the plate Place the kiosk by lining up the opening on the bottom of...

Page 4: ...with the Alcohol wipes included in the box Peel the film on the VHB on the bottom of the kiosk Place in desired location and firmly press down for full adhesive contact Allow 24 hours for full VHB ad...

Page 5: ...ed the Base will return to normal condition waiting for registered Access Card to unlock the Base The Base can register a maximum of 20 Access cards The process will need to be repeated for each card...

Page 6: ...e Red Handle Tool clockwise until resistance is felt about halfway and hold NOTE Do not grab the tablet until after you twist the Red Handle Tool Place the RFID Access Card until the base clicks NOTE...

Page 7: ...d Flashing Red Multiple undock attempts If an Access Card is swiped more the 10 times within 2 minutes the LED will flash Red and not allow undock attempts for 2 minutes click click x10 Remains Red wi...

Page 8: ...Service Example If a 21st card is registered the first registered card will be deregistered Example Example Take any of the remaining access cards and register it 20 consecutive times ACCESS005 ACCES...

Page 9: ...iosk with the teeth on the mounting plate Lock the kiosk into place by rotating it counter clockwise on the plate NOTE The Through Hole Mounting Accessory is sold separately Peel the film on the inclu...

Page 10: ...rrect the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outl...

Page 11: ...www MTIGS com T 801 653 3807 Print this document at 100 or Actual Size to assist in placing the RapidDoc Mounting Plate 3 9376 in 3 9376 in Drill Hole FRONT 3 hole for Optional Through Hole Mounting...