Page 1: ...Manual HORIZONTAL CLOSE COUPLED FLEXIBLE COUPLED Distributed in the UK by Pump Engineering Limited Unit B1 Riverside Industrial Estate Littlehampton West Sussex BN17 5DF United Kingdom Tel 01903 7309...

Page 2: ...turer s instructions for connecting the motor Note the correct rotation and wiring diagrams on the assembly Make sure the motor rotation and speed matches that required for the pump When making electr...

Page 3: ...components required for servicing plus bearings shaft and drive keys for flexible coupled pumps should be obtained A factory rebuild should be considered whenever your disassembly indicates rebuildin...

Page 4: ...ing Other means such as pipe hangers and pipe supports should be used to carry piping to avoid misalignment and distortion Consideration should be given to thermally induced expansion and contraction...

Page 5: ...turn over by hand after they have been allowed to dry out inside New pumps from the factory are tested using rust inhibitors to preclude this possibility On site system flushing may remove these inhi...

Page 6: ...age from dry run ning is eliminated Suction lines may be large reducing line losses and minimiz ing the potential of cavitation damage There are no check valves or priming devices to fail or require m...

Page 7: ...et face down on a clean flat surface Look into the opening in the center of the motor bracket and you will see a portion of the seat Insert the 11 16 dowel and very gently tap the seat until it drops...

Page 8: ...Place the large O ring 7 into the outside O ring groove in the motor bracket Place the two 2 smaller O rings 8 into the smaller O ring grooves 9 Place the cover 2 over the motor bracket and install t...

Page 9: ...have occurred during disassembly Re clean parts as necessary 5D Reassembly All parts should be visually inspected and cleaned or replaced as outlined in 5C above It is recommended that the bearings b...

Page 10: ...strainer or foot valve too small or clogged Inspect and clean out as necessary Fittings and lines should be at least equal to the pump suction size 8 Discharge head too high Install a pressure gauge...

Page 11: ...a few weeks the noise level will diminish and will be noticeably quieter as it approaches a run in condition 6G Mechanical Problems 1 Short bearing life Bearings damaged due to leaky seals Coupling m...

Page 12: ...that a Product has failed to meet its Operational Specifications the Purchaser must request a Return Goods Authorization RGA in the manner specified at http www mthpumps com and supply any additional...