background image

 

                 

 

High Frequency 
SineWave Guardian

TM

 

380V 

 480V 

INSTALLATION GUIDE 

 

FORM: SHF-IG-E 
REL. January 2018  
REV. 002 

© 2018 MTE Corporation 
 
 
 
 
 
 
 
 

 
 
 

 

WARNING

 

High Voltage! Only a qualified electrician can carry out the electrical 
installation of this filter.

 

 

Quick Reference 

 

How to Install 

Pages 6 

– 12 

 

Startup/Troubleshooting 

Pages 13 

– 16 

 

Summary of Contents for SineWave Guardian

Page 1: ...ION GUIDE FORM SHF IG E REL January 2018 REV 002 2018 MTE Corporation WARNING High Voltage Only a qualified electrician can carry out the electrical installation of this filter Quick Reference How to...

Page 2: ...ROUNDING 7 POWER WIRING CONNECTION 8 BASIC SCHEMATIC DIAGRAM 9 OPEN PANEL UNIT INTERCONNECTION DIAGRAM 10 ISOLATION TRANSFORMER DIAGRAM 11 TORQUE RATINGS 12 4 START UP 13 STARTUP CHECKLIST 13 5 TROUBL...

Page 3: ...l injuries or even death Caution Caution describes situations that can lead to malfunction or possible equipment damage WARNING High Voltage Warning warns of situations that dangerously high voltage i...

Page 4: ...Injury or death may result if safety precautions are not observed The filter must be grounded with a grounding conductor connected to all grounding terminals Open panel filters must have reactor grou...

Page 5: ...er The High Frequency SineWave Guardian Motor Protection Filter has been subjected to demanding factory tests before shipment Carefully inspect the shipping container for damage that may have occurred...

Page 6: ...chanical configuration Modular Modular units consist of a reactor and one or more capacitor panel assemblies referred to as cap panels on drawings and diagrams Additional wiring between the reactor an...

Page 7: ...o be aware of minimum electrical clearances as defined by the appropriate system safety standard s These filters generate heat and should be positioned away from heat sensitive components Avoid locati...

Page 8: ...and capacitor assemblies are shown in Table 3 2 p12 Refer to the drive user manual for instructions on interconnecting the drive and motor and the correct start up procedures for the drive The filter...

Page 9: ...High Frequency SineWave Guardian Installation Guide 380V 480V 9 mtecorp com Form SHF IG E January 2018 Rev 002 Basic Schematic Diagram Figure 3 1 Basic Schematic Diagram...

Page 10: ...High Frequency SineWave Guardian Installation Guide 380V 480V Form SHF IG E January 2018 Rev 002 mtecorp com 10 Open Panel Unit Interconnection Diagram Figure 3 2 Open Panel Interconnection...

Page 11: ...High Frequency SineWave Guardian Installation Guide 380V 480V 11 mtecorp com Form SHF IG E January 2018 Rev 002 Isolation Transformer Diagram Figure 3 3 Isolation Transformer...

Page 12: ...2x or 1 0 N A N A CAPPANEL 003 4 60 250 1 2x or 250K CMIL N A N A CAPPANEL 002 4 60 305 2 0 2x N A N A CAPPANEL 002 3 60 415 4 0 2x N A N A CAPPANEL 002 2X 4 each 60 515 300 MCM 2x N A N A CAPPANEL 00...

Page 13: ...ng internal components Connect a DC voltmeter across the capacitor terminals and ensure that the voltage is at a safe level Use extreme caution to avoid contact with line voltage when checking for pow...

Page 14: ...sture is present do not proceed with startup until the moisture has been removed 4 Disconnect filter output terminals from the motor 5 Set the drive switching frequency between 4 8 kHz and 8 kHz Refer...

Page 15: ...across the capacitor terminals or terminals U1 V1or V1 W1 and ensure that the voltage is at a safe level To aid in troubleshooting two interconnection diagrams and a troubleshooting guide that lists...

Page 16: ...ed motor rating Solution Verify the filter is properly sized for the application Possible cause Capacitors disconnected or improperly wired Solution Verify the proper connection of the capacitors Poss...

Reviews: