18 Function of the System
A
C
D
D
C
C
C
I
L
K
J
G
H
2
B
E
E
F
H
1
3.3 MTD-ERV 350
The MTD-ERV 350 consists as standard of the following components:
·
Outer casing (A) of coated sheet steel.
·
Inner lining (B) of high-quality expanded polypropylene (E)PP.
·
4 rotatable air-side connections (C) for the air ducts.
·
2 G3 fi lters (D) for air fi ltration.
·
2 energy-saving DC motors (E) with high-speed impeller.
·
(High-effi ciency) heat exchanger (with optional moisture exchanger) (F) with a thermal effi ciency ex-
ceeding 95% in which moisture as well as heat is recovered from the exhaust air.
·
CC Ease operating unit (G) for reading off data and for settings.
·
PCB panel (H2) with connections for the CC Ease operating unit, the enthalpy exchanger and the sen-
sors with 0 - 10 V controller (2x).
·
PCB panel (H1) with connections for the fans, bypass, preheater, temperature sensors (T1 to T4), 3-po-
sition switch with or without malfunction and fi lter display (option) and the bathroom switch (option).
·
Identifi cation plate (I) with the data on the MTD-ERV 350 (not visible).
·
Condensation drain (J) for discharging the condensation from the warm exhaust air.
·
Sticker (K) with the air connections (not visible).
·
230 V plug (L).