*PWR Indicator 

 

 

LED 

 

STATUS 

 

Description 

Power 

 

 

 

 

 

 

 

Green 

 

 

LED ON if power input has valid power 

supplied. (via the terminal block on rear 

panel or Port 8 on front panel) 

 

Red 

 

 

 

 

 

LED ON if the following condition 

happens. 

*Power input under voltage (Vin<12V) 

*Power input over voltage (Vin>58V) 

*PoE over current(2A) 

The indicator is unused on PSE-SW8D 

Off 

No power in DC input 

 

 

 

 

*SWITCH indicator (the right LED on RJ45) 

 

  LED 

STATUS 

Description 

P1~P8 

Link/Act 

     

 

 

 

 

Green 

 

A network device is detected at 100Mbps, 

but no communication activity is detected. 

 

Green 

Blinking 

 

This port is transmitting to, or receiving 

package from another device at 100Mbps. 

Yellow 

A network device is detected at 10Mbps, 

but no communication activity is detected. 

 

Yellow 

Blinking 

 

This port is transmitting to, or receiving 

package from another device at 10Mbps. 

Off 

No device is detected. 

   

Summary of Contents for PSE-SW8 series

Page 1: ...PSE SW8 series 8 Port PoE Switch Endspan Extend Ethernet and PoE USER S MANUAL MSTRONIC CO LTD...

Page 2: ...SE SW8 Series MSTRONIC CO LTD 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port PD Port Wiring 3 Network Application 4 Model Information 5 Technical Specificatio...

Page 3: ...ut voltage is equal to the input voltage The PoE Switch can be used as an Ethernet PoE repeater to extend Ethernet data and DC power up to 200 meters This manual will help you install and maintain the...

Page 4: ...t 2A The indicator is unused on PSE SW8D Off No power in DC input SWITCH indicator the right LED on RJ45 LED STATUS Description P1 P8 Link Act Green A network device is detected at 100Mbps but no comm...

Page 5: ...ximum for temporary but total output power MUST limited at 7A maximum If power input from port 8 the input current is limited at 2A maximum the output is 0 25A port For PSE SW8D The input voltage must...

Page 6: ...t you can use an AC DC adapter with DIN 4P connector directly recommends adaptor as detailed below OPTION MS 180 18 MS 180 24 MS 180 56 Maximum output 18VDC 8 33A 24VDC 6 25A 56VDC 3 21A Related model...

Page 7: ...t the opposite end Straight through Cabling Pin 1 Pin 1 Pin 2 Pin 2 Pin 3 Pin 3 Pin 6 Pin 6 Cross over Cabling Pin 1 Pin 3 Pin 2 Pin 6 Pin 3 Pin 1 Pin 6 Pin 2 Connect an Ethernet cable into any switch...

Page 8: ...o the PD It will power 802 3af compliant devices if it is powered at 48VDC although it will not perform the 802 3af handshake with the client device The PoE Switch can be installed in a more appropria...

Page 9: ...3at compliant 12 57VDC 12 57VDC Higher input voltage As input voltage non regulated non 802 3at compliant PSE SW8D 44 57VDC No input 44 57VDC As input voltage non regulated 802 3at compliant No input...

Page 10: ...3x full duplex back pressure half duplex Data transmission rate 148800pps for 100base T 14880pps for 10base T Address table 2K MAC address table self learning Connect RJ 45 PoE port Port 1 7 Pin assi...

Page 11: ...d alarm Power input DC 12V 57V from rear panel or DC 44V 57V from port 8 from midspan or network switch Power consumption 5W when without PD loading Input Voltage Input Current 12V 0 058A 24V 0 037A 4...

Page 12: ...e Data 16 5V I PP 5A t p 8 20 s I O pin to GND Peak Pulse Current 20A tp 8 20 s Pin Protected 4 pin protected signal pairs Max Shut Capacitance 3pF VR 0V f 1MHz I O pin to GND 1 5 pF VR 0V f 1MHz Betw...