1. General Information 

 

The PoE (Power Over Ethernet) Switch provide two 10M/100M/1000M TX ports with PoE PSE 

function plus one 10M/100M/1000M TX up-link port with PoE PD function., which is compliant 

with IEEE802.3af ,IEEE802.3at and IEEE802.3bt standard to receiver and deliver both of Ethernet 

data and DC power through the traditional UTP or STP cable. 

 

2. Hardware Description 

*LED Indicator 

 

There are 8 LEDs on the PoE switch to indicate the status of power and signal. The following 

section describes the functions of each LED indicator. 

 

Front panel detail 

 

 

 

 

*POWER LED 

 

 

LED 

 

STATUS 

 

Description 

Power 

Green 

 

LED ON when power input has valid 

power supplied. 

Red 

The indicator unused on this model. 

Off 

No power supplied. 

 

 

Summary of Contents for PSE-SW3B25D0H

Page 1: ...USER S MANUAL MSTRONIC CO LTD PSE SW3B25D0H PoE Switch...

Page 2: ...nual PSE SW3B25D0H MSTRONIC CO LTD 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port Wiring PD Port Wiring Network Application 3 Technical Specification 3 3 3 5...

Page 3: ...EE802 3bt standard to receiver and deliver both of Ethernet data and DC power through the traditional UTP or STP cable 2 Hardware Description LED Indicator There are 8 LEDs on the PoE switch to indica...

Page 4: ...is transmitting to or receiving package from another device at 10Mbps or 100Mbps Off No device is detected PoE LED the left indicator on RJ45 P1 P2 PoE Yellow A valid Powered Device PD is detected an...

Page 5: ...1 2 will deliver DC power over the Ethernet cable the connection as Data pair A plus V on line 1 and 2 Data pair B plus V on line 3 and 6 Data pair C plus V on line 4 and 5 Data pair D plus V on line...

Page 6: ...vides Power over Ethernet function that delivers DC power through the data pairs 4 pairs or 2 pairs to the PD The following tables describe the wiring diagram of straight through and crossover cabling...

Page 7: ...PoE switch follows the IEEE802 3af Alternative A MDI X B mode connector assignment The following table shows pin assignment of alternative A and B for the Power Source Equipment Conductor Alternative...

Page 8: ...LTD 8 Network Application The PoE Switch can receive power from PoE midspan and provide power to the PD which follows the IEEE 802 3af at bt standard in the network The following figure is an example...

Page 9: ...ion Switch technology Store and forward Protocols CSMA CD Flow control IEEE802 3x full duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T 14880pps...

Page 10: ...45 Link Activity Green ON Green Blinking 1000Mbps Yellow Yellow Blinking 10M 100Mbps PoE LED port1 2 the left indicator on RJ45 Yellow ON PD detect deliver power Power LED normal Green ON Power input...