background image

1 General 

1.1 Safety 

The operating instructions must be carefully read and followed by all persons who install, use, main-
tain and check the product.  
The product can only fulfill its intended functions if it is installed, used, maintained, cared for and 
checked in accordance with the instructions provided by 

INTEC Controls | MSR-Electronic GmbH

1.2 Responsibility Installer and Operator 

It is the responsibility of the installer and operator to ensure that all PolyGard

®

2/PolyXeta

®

2 equip-

ment  is  installed  and used in  compliance  with  all  national  and  local  codes.  The  device  must  be 
checked for correct installation and functionality by a qualified person before measurement opera-
tion is started. In Germany, BGR 500 Chapter 2.33 must be applied for this purpose.  
The PolyGard2 devices are tested for function by the manufacturer before delivery. During commis-
sioning, a documented functional test is also required. The installation should only be carried out by 
trained installation technicians, taking into account the current safety procedures for control instal-
lations. 
The required equipotential bonding connections (also e.g. secondary potential to ground) or ground-
ing measures are to be carried out according to the respective project regulations. It must be ensured 
that no ground loops are created in order to avoid undesired interference in the measurement elec-
tronics.  
It is necessary to follow all instructions as well as the user documentation. 

1.3 Maintenance 

It is recommended that PolyGard

®

2/PolyXeta

®

2 equipment be inspected on a regular basis. Perfor-

mance deviations can be corrected based on regular maintenance. Recalibration and parts replace-
ment can be performed in the field by a qualified technician using the appropriate tools.  
Alternatively, the easily removable, plug-in sensor head can be returned to 

INTEC Controls | 

MSR-Electronic GmbH

 for service.  

Regular maintenance is to be carried out according to the instructions. 

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com

Specifications subject to change without notice. | GA_GC06_Modbus_supplement_E, 2022-04-05 | USA 221209 | Page 4 of 12

DGC6 Modbus Supplement – UserManual

Summary of Contents for Intec Controls PolyGard 2 DGC6

Page 1: ...C 06 Modbus Modbus Supplement Version 2022 04 Release date 2022 04 05 Language English Name of file GA_GC06_Modbus_supple ment_E INTEC Controls 12700 Stowe Drive Suite 100 Poway CA 92064 Ph 858 578 78...

Page 2: ...This page intentionally left blank...

Page 3: ...ng bits of digital sensors 8 3 8 Display of the alarms and the respective latching bits of analog sensors 8 3 9 Relay status of the signal relays signal relay addr 1 96 Modbus register addr 7001 7096...

Page 4: ...ng into account the current safety procedures for control instal lations The required equipotential bonding connections also e g secondary potential to ground or ground ing measures are to be carried...

Page 5: ...ement has been poisoned The above warranty is in lieu of all other express warranties obligations or liabilities A pre authorized RMA number issued by INTEC Controls is required for returns This warra...

Page 6: ...s inactive The resistor circuitry is already integrated in a Modbus master controller 3 Modbus Function 03 Reading of Registers Read Holding Registers reading of holding registers is used to receive d...

Page 7: ...verage value of analog sensors sensor addr 1 32 Modbus register addr 4001 4032 Figure 4 Average value of analog sensors sensor addr 1 32 Modbus register addr 4001 4032 3 5 Measuring range of digital s...

Page 8: ...g sensors Here the representation in the hexadecimal form is easier to read because the data are transmitted in the following form 0xFFFF 0x F F F F 0b 1111 1111 1111 1111 Local latching DGC 06 latchi...

Page 9: ...fault message relay is in register 8000 The following values are possible 1 Relay is not active 0 Relay is active not energized 1 Relay is active energized 3 11 Error codes Modbus register addresses 9...

Page 10: ...se these are dis played in the registers of the measured values c Register address 9097d 9104d Local error of the 8 Gas Controller Modules 1x GC06 7x EP06 Here 0x8100 MP error Error with any locally c...

Page 11: ...its of the extension module address_2 Relay 9 is bit 0 to relay 12 is bit 3 Address 4 Relay information bits of the extension module address 3 Relay 13 is bit 0 to relay 16 is bit 3 Address 5 Relay in...

Page 12: ...al registers in the DGC 06 Currently it is only possible to write on the own slave address Modbus address 0 see chapter 3 12 6 Modbus Function 15 Write Multiple Coils Write Multiple Coils writing mult...

Reviews: