Manual ERS (Energy Recovery System)
MSF-Vathauer Polska Sp. z.o.o ul. Staszica 37 PL-64-600 Oborniki
Tel: 0048 503972873 E-mail
www.msf-technik.pl
Page 17 of 23
The 24Vdc is executed with a tolerance of +/- 10%.
5.5. Integrated braking resistor
Error-free operation of the ERS requires a three-phase supply network. If this network fails or one of
the three phases is missing, then the devise goes into malfunction and can not return any regenerative
energy. In this case, there is the possibility to use the built in emergency resistor. However, this
assumes that of the frequency inverter or servo controller in use has a built-in brake chopper
connection and that the integrated resistor meets the application requirements.
The emergency resistor is permanently loaded with 100W.