Use
14
MSA/XTIRPA™ Adapter Base System 24" Reach
US
US
Caution
Keep work area free from obstructions, trip hazards, and spills which
could impair the safe operation of the fall-rescue system
.
Do not open the confined space access cover before complete
installation of the anchorage connector and all other system
components.
3.2. Pre-Use Inspection
Inspect the confined space system to verify that it is in serviceable
condition. Examine every inch of the confined space system for severe
wear, missing or broken elements, corrosion, or other damage. Do not
use the confined space system if inspection reveals an unsafe condition.
3.3. Assembly
Always work in teams of at least two (2) people (one (1) attendant and
one (1) confined space worker) who are qualified and trained on the
confined space system.
(1.) Remove all components and parts from bags, boxes, or shipping
container and set all on ground. Make sure that components are in
good working condition.
(2.) Insert the mast into the Adapter Base sleeve (A) and lock with a
pin (B). If using integrated mast and davit arm IN-2295 or IN-2363,
proceed to Step 5.
Fig. 8
Step 2A
Fig. 9
Step 2B
Visit: www.thesafetyequipmentstore.com Or Email: [email protected] for Sales & Service.