background image

ACCESSORIES

The facepiece may be equipped with the following acces-
sories:
1. Communication System
2. Cover Lens (clear or tinted), in small, medium, or large
3. Spectacle Kit

Refer to the NIOSH Approval Matrix for a complete list
of Approved Accessories. If you must wear corrective
eyewear, install an approved spectacle kit, listed on
the NIOSH approval matrix insert.

Know the contaminant(s) in the environment before
entering. Always check that the filter canis-
ter/cartridge(s) is appropriate for use in the environ-
ment. A filter canister/cartridge(s) which is not
designed for the contaminant present may not provide
protection. Failure to follow this warning can result in
serious personal injury or death.

Installing the Nosecup for Ultravue Facepiece

1. Place the nosecup in the facepiece and position it so

its rubber ring faces toward the plastic retainer ring.

2. Starting at the top,

stretch and push the
rubber ring of the nose-
cup under the plastic
retainer ring of the
speaking diaphragm
assembly.

3. Continue stretching the nosecup ring and work it into

place.

4. For Ultravue masks only, stretch the oval opening in

the nosecup around the lip on its component housing.

Spectacle Kit

Spectacle kits are available for the Ultravue (P/N 454819).
The kit includes the support assembly, a rubber block,
and the spectacle frame. Prescription lenses can be
obtained locally or through MSA.

Adjusting the Spectacles

1. To move the spectacles closer to your face, pull the

frame prongs out of the rubber block.

2. To move the spectacles farther from your face, push

the frame prongs into the rubber block.

3. To move the spectacles

up or down, slide the
rubber block up or
down on the support
arms.

Attaching the Gas Mask Chin Canister to the Belt

This conversion kit consists of:

Installation Instructions

1. Attach the male thread end of the breathing tube

securely to the facepiece component housing.

2. Slide the belt clip over the neck of the canister.
3. Securely fasten the female end of the breathing tube

to the male end of the canister.

4. Attach the belt around the waist and attaché the belt

clip to the belt.

Spark Cover (Recommended for Belt-Mounted Chin
Style Gas Mask Canisters)

1. Remove canister and spark cover from the packaging.
2. Attach the canister to the facepiece or breathing tube

depending on the configuration being used.

3. Once the canister is attached, align the feet of the

spark cover with the inlet hole of the canister.

4. Grasp the outside of

the canister, twist and
push on the spark
cover. The spark cover
will snap in place.

21

TAL 804 (L) Rev. 5 - 10068239

Quantity

Item

Part Number

1

Belt Clip

10068195

1

Breathing Tube

10068129

1

Belt

473902, 9961, 492827

1

Spark Cover

10068152

motion for attaching

spark cover

Summary of Contents for Ultravue GME-P100

Page 1: ...H Approval Information P N 10035719 P100 GME P100 P N 818206 Ultra Twin P N 817241 Gas Mask P N 818082 CS CN This manual must be carefully read and followed by all persons who have or will have the re...

Page 2: ...o User s Instructions before donning LL This respirator contains filter or cartridge components that are not approved for protections in all configura tions Check the specific row in the NIOSH approva...

Page 3: ...te or smell the contaminant d You experience nose or throat irritation e Instructed by responsible individuals 12 Use strictly according to the instructions labels and limitations pertaining to this d...

Page 4: ...4 TAL 804 L Rev 5 10068239 NOTES...

Page 5: ...es the exposure limit for the contaminants present if using a quantitative fit test method Using a qualitative fit test may reduce the maximum use concentration See the Respirator Fit Test section b I...

Page 6: ...a mix ture of chlorine and mercury that are both present simultaneously but cannot be used if alternating between mercury contaminated atmospheres and chlorine contaminated atmospheres E TIME USE LIMI...

Page 7: ...ned to ensure proper fit before using the respirator If other than facial seal leakage is detected the condition must be investigated and corrected before another test is made The facepiece must also...

Page 8: ...8 TAL 804 L Rev 5 10068239 NOTES...

Page 9: ...oring the canister outside the packaging Discard canister cartridge s after each use Replace the canister cartridge s after each use Follow the established canister cartridge s change out sched ules t...

Page 10: ...he replacement cartridges from the storage bags and insert them into the threaded receptacles making sure the gaskets are in place in the recepta cles 6 Carefully hand tighten the cartridges to preven...

Page 11: ...back of the head 4 Support the weight of the mask by holding the outlet valve assembly in the palm of the hand with the free hand adjust the facepiece securely to the face mak ing sure the chin and n...

Page 12: ...t again 5 If this does not correct the leak the mask will not pro vide protection If the leakage is from the face seal a different size mask may provide a good seal If other than face seal leakage is...

Page 13: ...must be per formed Disposal is to be performed as required by feder al state and or local laws PROCEDURE FOR REMOVING THE RESPIRATOR 1 To remove the facepiece insert your thumbs under each of the har...

Page 14: ...14 TAL 804 L Rev 5 10068239 NOTES...

Page 15: ...tions with the Confidence Plus Cleaning Solution b If the Confidence Plus Cleaning Solution is not used wash in a mild cleaning solution rinse thor oughly and submerge in a germicide solution for the...

Page 16: ...16 TAL 804 L Rev 5 10068239 NOTES...

Page 17: ...the white inhalation disc valve is attached to the spider gasket The disc must be free of cracks tears dirt and distortion 9 Set the gasket with inhalation valve disk aside in a clean location 10 Expo...

Page 18: ...18 TAL 804 L Rev 5 10068239 NOTES...

Page 19: ...sing the supplied cap plug component Remove the canister from the box and bag Locate the white block on the canister label Mark on the canister in the white block an expiration date of 1 year for form...

Page 20: ...e with the plug side of the cap and plug component secured into position The respirator must be placed upright in the plastic case P N D2056734 DO NOT store the canister above 120 F Failure to fol low...

Page 21: ...s the support assembly a rubber block and the spectacle frame Prescription lenses can be obtained locally or through MSA Adjusting the Spectacles 1 To move the spectacles closer to your face pull the...

Page 22: ...ark cover is optional OTHER RESPIRATORY CONFIGURATIONS This respirator can be used in other configurations that stated in these User s Instructions Below is a list of these other configurations and th...

Page 23: ...ULTRAVUE FACEPIECE 23 TAL 804 L Rev 5 10068239...

Page 24: ...agent employee or representative of MSA may bind MSA to any affirmation representation or modification of the warranty concerning the goods sold under this con tract MSA makes no warranty concerning...

Reviews: