Entering System Parameters
GB
SUPREMATouch
Display
This window displays parameters that affect the entire system.
Fig. 28 Display
Field
Field Type
Function
Language
Selection,
English by
default
Set the language for the user interface (GUI).
Buzzer
Number Input,
Range is 0 to
100; 100 by
default
Sets the loudness of the internal beeper.
Dimming
Number Input,
Range is 0 to
100; 100 by
default
Sets the dimming of the display.
Signal if Inhib-
ited
Selection,
pass by
default
If a MAO module is used to output sensor signals, there are
three different ways of analogue signal behavior for inhibited
inputs:
• pass: The received measurement values are sent on.
• hold: The last measured value before inhibiting occurred is
retained.
• maintain: The signal goes to the maintenance level (corre-
sponds to 3.0 mA).
The setting is essential for all measuring points in the whole
system.
Operating
Mode
Display, Stan-
dard by
default
Shows the current operating mode of the SUPREMATouch
system. Only two operating modes are available:
‘Standard’ for all countries except China and ‘GB16808-2008’
which is only for use in China. All information, including the
approval information in this manual refer to the
Standard
oper-
ating mode.
OK
Button
Tap this button to accept the settings entered. After the button
is tapped, the parameters are immediately checked to see if
they are valid. If the parameters are valid, they become part of
the system’s parameter set. If they are not valid, a warning
appears.
Cancel
Button
Tapping this button cancels the settings entered.
Summary of Contents for SUPREMATouch MCP 20
Page 1: ...MSAsafety com Operating Manual SUPREMATouch Fire and Gas Warning Unit Order No 10121863 05...
Page 8: ...MSAsafety com User Instruction Manual SUPREMATouch Fire and Gas Warning Unit...
Page 72: ...MSAsafety com Service and Maintenance Guide SUPREMATouch Fire and Gas Warning Unit...
Page 232: ...232 Dimensions GB SUPREMATouch 18 Dimensions 18 1 Rack...
Page 233: ...233 Dimensions GB SUPREMATouch 18 2 Rail mounted Modules MRO8 TS Module MRO16 TS Module...
Page 235: ...235 Dimensions GB SUPREMATouch MRO20 8 TS Module 1 3 2 69 90...
Page 236: ...236 Dimensions GB SUPREMATouch MRO20 16 TS Module 2 5 2 64 73 relay dependent 90...
Page 237: ...237 Dimensions GB SUPREMATouch MRC TS Module MGT40 TS Module...
Page 238: ...238 Dimensions GB SUPREMATouch MHD TS Module MAT TS Module...
Page 241: ...For local MSA contacts please visit us at MSAsafety com Because every life has a purpose...