SSR 30/100 / SSR 30/100 B
4
Safety Regulations
GB
1
Safety Regulations
1.1
Correct Use
The SSR 30/100 respectively the SSR 30/100 B self-rescuer are respiratory protection devices [chem-
ical oxygen apparatus] for self-rescuing which are independent of the ambient atmosphere. They
protect the wearer of the devices during escape from a dangerous ambient atmosphere or whilst
waiting for rescue from poisonous gases, toxic particles and oxygen depletion. It is to be used exclu-
sively for self-rescue under dangerous conditions and is not intended for long-term use.
The device described in this operating manual complies with Directive 89/686 EEC or Regulation (EU)
2016/425, respectively.
The device has been tested and certified by DEKRA Testing and Certification GmbH,
Dinnendahlstrasse 9, 44809 Bochum (Germany), Notified Body 0158.
The device is developed for one mission, used devices must always be replaced, reuse is not
permitted.
It is imperative that this operating manual be read and observed when using the device. In particular,
the safety instructions, as well as the information for the use and operation of the device, must be care-
fully read and observed. Furthermore, the national regulations applicable in the user's country must be
taken into account for a safe use.
Alternative use, or use outside this specification will be considered as non-compliance. This also
applies especially to unauthorised alterations to the product and to commissioning work that has not
been carried out by MSA or authorised persons.
1.2
Liability Information
MSA accepts no liability in cases where the device has been used inappropriately or not as intended.
The selection and use of the device are the exclusive responsibility of the individual operator.
Product liability claims, warranties and guarantees made by MSA with respect to the device are voided,
if it is not used, serviced or maintained in accordance with the instructions in this manual.
1.3
Safety and Precautionary Measures
WARNING
The device may only be used once and must never be reused. Used or opened devices must be
replaced by new devices.
WARNING
This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the
function of the device and thereby seriously compromise the user's life.
Before use the product operability must be verified. The product must not be used if the function test
is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine
MSA spare parts have not been used.
Attention!
Chemical Oxygen Escape Devices used in mining may be subject to particular Mining-Regulations
that are to be observed.
There is an ignition danger in case the device is destroyed and the oxygen generating chemical
comes into contact with combustible substances,e.g. coal.
Also observe official regulations applicable in the country of use.
Attention!
Defective devices must not be used!
Removed defect devices from service and return them to MSA for inspection.