SavOx TR / SavOx Industry TR
8
Use
GB
Detaching the Device
(8)
Detach device from mouthpiece plug.
Activating the Device
(9)
Grasp breathing tube at the mouthpiece.
(10) Fully extend the breathing tube to activate the starter.
A drop in pull resistance indicates the starter is initi-
ated.
Inserting the Mouthpiece
(11) Place mouthpiece into mouth with flange of mouthpiece
between teeth and lips.
(12) Bite down on the two lugs.
(13) Exhale into the device.
So the breathing bag is inflated.
It might be necessary to unfold the breathingbag by
hand.
Fit the Nose Clip
(14) Grasp nose clip by rubber pads, pull nose pads apart and
fit them onto nose.