17
Version 3.4
Summator-combiner of NMEA signal (sentences)
NC-217
2.3.3
The Product’s settings
2.3.3.1
Make settings for input and output ports by means of the user menu. To
access the menu, in the mode of active channel display press
Enter
after backlight activation
(see cl. 2.3.1). Once it is done, the Product transfers to the mode where a user can select an
input (output) to configure, see figure 12.
Figure 12 – Select of input (output) to configure
Using keys ▼ and ▲ select a port and press
Enter
. Then, a configuration menu of
the selected port will open, see figure 13.
Figure 13 – Configuration menu of the selected port
Using keys ▼ and ▲ select a parameter (“Baudrate”, “Stop bits”, “Parity”,
“CRC checking”, “Messages” (for ports “OUT1” to “OUT 12”)) and press
Enter
. Make
further settings depending on the selected parameter.
Note – To return to port select menu, as well as exit the port select menu and access
the mode that displays inputs (outputs) status, press ◄ key.
2.3.3.2
Select “Baudrate” in the menu to provide the settings, LCD will display the
following information, see figure 14.
Figure 14 – Select of port rate
Using keys ▼ and ▲ choose baud rate from the list: 4800, 9600, 14400, 19200,
28800, 38400, 57600, 76800, 115200 bit/s. Press
Enter
.
The Product will save the baud rate
in the non-volatile memory and return to the parameter select menu.
Note – If a user needs to cancel the made settings, press ◄ button to return to the
parameter select menu.
2.3.3.3
Select “Stop bits” in the menu to provide the settings, and LCD will display
the following information, see figure 15.