MSA ICM TxR Unit Operation Instructions Manual Download Page 12

a. To evacuate a single firefighter logged on to a base

station; click the Evacuate icon      located in the
firefighter’s SCBA statistics display window.  
• When the evacuation signal is sent to a firefighter,

the Evacuate icon in the firefighter’s SCBA statis-
tics display window will turn RED.  

• When the ICM TxR Unit receives the evacuation

command, the PASS device will begin to emit an
audible evacuation alarm, display a flashing run-
ning man icon on the LCD, and display alternating
RED/ORANGE LEDs in the NightFighter receiver. 

• When an ICM TxR Unit successfully receives the

evacuation signal, it will automatically return a sig-
nal to the base station to confirm that the signal
has been received.  If the signal is not received,
the base station will continue to send a signal to
that unit until the radio transmission is successful.

• When the base station receives a confirmation sig-

nal from the evacuated ICM TxR Unit, the
Evacuate icon for that firefighter will turn YELLOW. 

b. The firefighter must then manually press the reset

button on the ICM TxR Unit twice in rapid succes-
sion in order to acknowledge the evacuation com-
mand and silence the evacuation alarm.  
• Once the firefighter manually acknowledges the

evacuation command, the Evacuate icon will turn
GREEN.  

PAR TIMER

The ICM TxR Accountability Software provides a PAR
(Personnel Accountability Report) Timer to serve as a
reminder when the specified PAR time interval has been
reached during an incident. By default, the PAR time
increment is 15 minutes.  This setting can be changed in
the settings menu.  Refer to the Configuring the SCBA
Monitoring Settings section of this manual.  

Using the PAR Timer

1.  Click the “Start” button in the upper right portion of

the SCBA monitoring window. 

2.  The PAR timer will then begin counting up from 00:00.  
3.  When the specified PAR time interval has been

reached (every 15 minutes by default), a pop-up alarm
window will be displayed and the PC will emit an audi-
ble tone.  

4.  The PAR timer will continue and another PAR alarm

will appear and sound when the next PAR time interval
has been reached.  For example, default the PAR
alarm will occur at 15, 30, 45…..minutes.    

LOSS OF RADIO COMMUNICATION

If a firefighter travels out of the range of radio transmis-
sion, the PC software will display several indications that
the radio link has been lost. These indications are
described below.  When a firefighter is out of range, any
signals sent from ICM TxR Unit to the base station, or
from the base station to the ICM TxR Unit, cannot be real-
ized until the radio link has been re-established.  Both the
ICM TxR Unit and the base station will repeatedly send a
signal until the link has been regained.  

Note: 

A loss of radio communication may occur when a

firefighter is in an area of a structure that is not conducive
to proper radio transmission.  Structures that are under-
ground or constructed of thick concrete and metal are not
conducive to good radio signal transmission.  Areas
where traditional two way radio communication is difficult
may induce a temporary loss of radio contact between
the ICM TxR Unit and the base station.  

Indications that a firefighter has lost radio communi-
cation with the base station 

The antenna icon in the firefighter’s SCBA statis-
tics window will turn gray and a RED X will
appear over the icon.  

A gray antenna icon with a RED X over it will
appear next to the helmet icon for any firefight-
er that has lost radio communication.  

In the SCBA statistics display window, directly below
the service time remaining display, a red text counter
will appear when a firefighter is out of range of radio
contact.  This counter will continue to count the num-
ber of minute that a firefighter has been out of radio
contact with the base station.  The counter will disap-
pear when the radio link has been regained.  

On the ICM TxR Unit, the radio link indicator (antenna
icon) in the upper right portion of the LCD will begin to
flash when the unit has lost radio communication.  

USING MULTIPLE BASE STATIONS

Two Base Stations on a Single PC 

A single base station can monitor up to 50 firefighters at
one time.  If there is a need to monitor more than 50 fire-
fighters at one time, an additional base station may be
attached to the same PC to allow up to 100 firefighters to
be monitored.

As the number of firefighters approaches 50 on a
given base station, MSA recommends that the PC at
least meet the optimum PC system requirements rec-
ommended in this manual.  Failure to do so may cause
the PC to loose its ability to effectively monitor all of
the firefighters at the incident.  It is up to the user to
determine whether or not the PC being used is capa-

USING THE ICM T

X

R ACCOUNTABILITY SOFTWARE

12

TAL 605 (L) Rev. 0 - 10068929

Summary of Contents for ICM TxR Unit

Page 1: ...guarantee that interference will not occur in a particular installation If this equip ment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equip...

Page 2: ...ure to Radio Frequency RF Signals The wireless ICM TxR Unit is a radio transmitter and receiver It is designed and manufactured not to exceed the emission limits for exposure to radio frequency RF energy set by the Federal Communications Commission of the U S Government These limits are part of compre hensive guidelines and established permitted levels of RF energy for the general population The g...

Page 3: ...ry or death DESCRIPTION OF ICM TXR UNIT AND BASE STATION INTERFACE The ICM TxR Unit on the SCBA is designed to communi cate with the base station and PC This system provides the ability to monitor firefighters from a remote location When an SCBA is pressurized the ICM TxR Unit is auto matically activated It then waits to receive a signal from the base station to begin the log on process After all ...

Page 4: ...4 TAL 605 L Rev 0 10068929 NOTES ...

Page 5: ...outlet 2 Connect the antenna to the base station by threading the TNC fitting on to the jack on the right side of the base station Note The base of the antenna has a magnetic platform It is recommended that it be placed in an area that is above the base station and is free from obstruction such as the roof of a vehicle Use only antennas provided by MSA for use with this base station Failure to do ...

Page 6: ...6 TAL 605 L Rev 0 10068929 NOTES ...

Page 7: ...or each fire fighter By default the following color scheme has been chosen to remain consistent with that of the heads up display to build consistency within the fire scene New Person BLUE Cylinder Pressure above 50 GREEN Cylinder Pressure between 25 and 50 YELLOW Cylinder Pressure below 25 RED g Allow single evacuation permits a single fire fighter to be sent an evacuation command 4 Under the Ala...

Page 8: ...eplace the alarm sound for the motion alarm rename the desired wav file to Sound1 wav before select ing To replace other sound files simply rename the desired wav file so that it matches the default name shown for that alarm 5 Under the Default cylinder pressure tab the default cylinder types and estimated service times can be edited These default cylinder types are for use when firefighter s with...

Page 9: ...n the holding bin 5 The full logon process for a given unit is less than 1 minute a During the log on process the PC acquires data such as name ID Team assignment pressure type and current pressure from the ICM TxR Unit b During the log on process the helmet icon may jump from the holding bin into a team automati cally if a team ID was assigned to the ICM TxR Unit using an ID Tag c Refer to the ID...

Page 10: ...etrieve previously entered team names from past sessions click the drop down menu arrow at the far right side of this text box All past team names will be displayed for selection Adding Comments to a Team 1 Click in text box under the team name text box 2 Type any additional team comments and press enter Note To retrieve previously entered comments from past sessions click the drop down menu arrow...

Page 11: ...es a confirmation sig nal from an ICM TxR Unit that the evacuation com mand has been received the Evacuate icon for each firefighter will turn YELLOW on the PC screen b The firefighter must then manually press the reset button on the ICM TxR Unit twice in rapid succes sion in order to acknowledge the evacuation com mand and silence the evacuation alarm As each firefighter manually acknowledges the...

Page 12: ...e will display several indications that the radio link has been lost These indications are described below When a firefighter is out of range any signals sent from ICM TxR Unit to the base station or from the base station to the ICM TxR Unit cannot be real ized until the radio link has been re established Both the ICM TxR Unit and the base station will repeatedly send a signal until the link has b...

Page 13: ...nt report log for each SCBA monitoring session Incident reports may be accessed in the main screen of the MSA ICM TxR Accountability software by selecting INCIDENT SCBA MONITORING INCIDENT REPORTS To access incident reports while the SCBA monitoring window is open click the Incident Report button at the top of the SCBA monitoring win dow The Incident Window during SCBA monitoring Before an SCBA mo...

Page 14: ...out window 4 Select one 1 of the four 4 options to determine how the report will be sorted by either DOUBLE clicking the type of report or by SINGLE clicking the type of report and then clicking Preview The options are as follows a Sorted by name Displays all reports meeting the search criteria sorted by each firefighter s name in alphabetical order Under each Firefighter s name is a list of all i...

Page 15: ... of the options under the field labeled Format Formats available for export are pdf rpt html xls rtf odbc rec txt csv ttx and xml Click OK when finished b The Export Options window will appear Select the pages of the report to be exported and click OK c The Choose export file window will appear Select the name and directory to which the report should be saved USING THE ICM TXR ACCOUNTABILITY SOFTW...

Page 16: ...NOTES 16 TAL 605 L Rev 0 10068929 ...

Page 17: ...ll create a helmet icon for this fire fighter Notice that the helmet icon has a black box on it This indicates that the simulated breathing for this firefighter has not been started 7 To START to simulate breathing for this firefighter click the GREEN PLAY icon in the firefighter s SCBA sta tistics window Notice that the black box on the hel met icon becomes a black triangle When the GREEN arrow h...

Page 18: ...NOTES 18 TAL 605 L Rev 0 10068929 ...

Page 19: ... eight 8 zeros can be scanned into the ICM to remove the base station pref erence The SCBA monitoring window must be closed before the tag writer portion of the software can be used Failure to close this window may cause the ID Tag Writer to not respond and may prevent the use of the Tag Writer feature until the SCBA monitoring window has been closed The ICM Tx TxR Unit Data Program software must ...

Page 20: ...number located on the bottom of the base station The base station serial number is also displayed at the top of the SCBA monitoring window of the MSA ICM TxR Accountability Software 4 Type the base station serial number in the white text entry box 5 Insert an ID tag into the open slot on the front of the ICM Tag Writer 6 Click the Write button 7 A small dialog box should appear to confirm that the...

Page 21: ...ountability Software when arriving at an incident store the PC and base station in a vehicle with power supply antenna and USB connections in place Once the ICM TxR Accountability Software has been started this pro gram can remain open while in storage so that when arriv ing on the scene of an incident only the SCBA monitoring window needs to be opened to begin monitoring SCBA Failure to close the...

Page 22: ...NOTES 22 TAL 605 L Rev 0 10068929 ...

Page 23: ...ce with MSA s instructions and or recommendations Refer to MMR Air Mask with Firehawk operation and instructions manual PN 10023638 for additional warranty information For a copy of the complete warranty or for information on submitting a warranty claim write to MSA Customer Service Department P O Box 426 Pittsburgh PA 15230 0426 or call 1 800 MSA 2222 For further information or training instructi...

Page 24: ...NOTES 24 TAL 605 L Rev 0 10068929 ...

Page 25: ...Station Interface The LCD on the ICM TxR Unit serves as the firefighter s interface with the inci dent command base station 5 Redundant Low Pressure Alarm When the SCBA cylinder pressure falls below 25 percent of the rated service pressure a flashing RED light will appear in the Nightfighter Heads Up Display Receiver A RED LED will also flash on the ICM TxR Unit during this condition For the Incid...

Page 26: ...NOTES 26 TAL 605 L Rev 0 10068929 ...

Page 27: ......

Page 28: ......

Reviews: