INTRODUCTION

BB - Not for use in entry into atmospheres immediately

dangerous to life or health.

CC - For entry, do not exceed maximum use concentra-

tions established by regulatory standards.

GG - Direct contact with CBRN agents requires proper

handling of the respirator after use. Correct dispos-
al procedures must be followed.

QQ - Use in conjunction with personal protective ensem-

bles that provide appropriate levels of protection
against dermal hazard. Failure to do so may result
in personal injury even when the respirator is fitted
properly, used, and maintained.

UU - The respirator should not be used beyond eight (8)

hours after initial exposure to chemical warfare
agents to avoid the possibility of agent permeation.
If liquid exposure is encountered, the respirator
should not be used for more than two (2) hours.

VV -

PAPRS with TC-23C approvals may NOT be used
for escape from IDLH atmospheres.

S – SPECIAL OR CRITICAL USER’S INSTRUCTIONS

1. During use of the FireHawk M7 Responder PAPR, the

atmosphere must be monitored for the level of conta-
mination and a means of escape must be provided in
the event that the contamination level increases to
immediately dangerous to life and health (IDLH) levels.

2. The C420 PAPR must be properly inspected before

use, properly decontaminated, if necessary, after use,
properly cleaned and maintained after use, and prop-
erly stored between uses.

3. The C420 PAPR contains a battery and may not be

taken into or used in atmospheres containing flamma-
ble or explosive gases, vapors, or dusts when the
concentration of such contaminants is near or above
the lower flammable limit (LFL).

4. Do not use the C420 PAPR for firefighting, in oxygen-

deficient atmospheres, or for protection against air-
borne contaminants from which the canister does not
protect.

5. Firehawk

®

Regulator must always be connected to the

inlet adapter when used as a CBRN APR Respirator or
CBRN PAPR Respirator.

6. The Firehawk Regulator is a non-functional compo-

nent as regulator, but is functional as a plug for the
front port.

DO NOT attach the regulator to supplied air while
using the respirator as a CBRN APR or CBRN PAPR.
Failure to follow this warning can result in serious per-
sonal injury or death.

This respirator is approved for APR OR PAPR only
configurations and is not intended to be combined
with other apparatus. Failure to follow this warning
can result in serious personal injury or death.

7. The FireHawk M7 Heads-Up-Display (HUD) compo-

nents are non-functional component while attached to
the FireHawk M7 Responder APR when used as a
CBRN APR or CBRN PAPR.

8. The FireHawk M7 HUD is an optional component for

FireHawk M7 Responder APR or PAPR. The HUD can
be removed or attached prior to use.

9. The mouth-bit can be inserted or removed from the

nosecup prior to use. Please read the “Preparing the
Respirator for Use” section for proper procedure.

Follow instruction in the “Preparing the Respirator for
Use” section of the FireHawk M7 Responder APR user
instructions before inserting or removing the mouth-
bit in the nosecup. Failure to follow this warning can
result in serious personal injury or death.

The nosecup must always be installed when using the
FireHawk M7 Responder APR or PAPR. Failure to fol-
low this warning can result in serious personal injury
or death.

When using filters in an application that produces
sparks, ensure that they are protected by a shield.
Contact with sparks can damage filters and reduce
protection.

3

TAL 804 (L) Rev. 0 - 10086003

Summary of Contents for FireHawk M7 Responder PAPR

Page 1: ... perform as designed only if they are used and serviced according to the instructions OTHERWISE THEY COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY ON THESE RESPIRATORS COULD SUSTAIN SERIOUS PER SONAL INJURY OR DEATH The warranties made by MSA with respect to the product are voided if the product is not used and serviced in accordance with the instructions in this manual For any additional...

Page 2: ...rs are replaced before breakthrough occurs I Contains electrical parts that may cause an ignition source in flammable or explosive atmospheres J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s User s Instructions for changing canisters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA a...

Page 3: ...PAPR for firefighting in oxygen deficient atmospheres or for protection against air borne contaminants from which the canister does not protect 5 Firehawk Regulator must always be connected to the inlet adapter when used as a CBRN APR Respirator or CBRN PAPR Respirator 6 The Firehawk Regulator is a non functional compo nent as regulator but is functional as a plug for the front port DO NOT attach ...

Page 4: ...NOTES 4 TAL 804 L Rev 0 10086003 ...

Page 5: ...must be used in conjunction with the proper canisters for protection against specific contaminants If you cannot determine that the canisters used with this device is designed for the contaminant or if you do not know the identity of the contaminant do not use this device 8 DO NOT use when concentrations of contaminants are unknown 9 DO NOT block the canisters 10 DO NOT use when appropriate exposu...

Page 6: ...he expected air flow through the canis ters An average airflow of approximately two cubic feet per minute 2 CFM will flow through each canister during prolonged use The single use battery may be used up to eight 8 hours under certain conditions The rechargeable battery may be used for up to four 4 hours under certain conditions Air flow must be checked as described in these instruc tions for maxim...

Page 7: ...he limitations outlined in the applicable NIOSH approval 3 Any applicable limitation contained in a standard established by a regulatory agency such as OSHA with jurisdiction over the wearer 4 This respirator can be used for protection against a mixture of contaminants that are present simultane ously or alternately against one contaminant then another using the same canisters or filters if the mi...

Page 8: ...ck or a rechargeable 4 8 volt nominal nickel metal hydride NiMH battery pack Weight Blower assembly with battery pack and two can isters approximately 4lbs Contents The C420 PAPR filtering system kit is shipped with the components listed Note Upon receipt of PAPR kit inspect the contents for shipping damage and ensure all components are present C420 Motor Blower Assembly PAPR Breathing Tube Extens...

Page 9: ...y Pack use the green battery cap assembly sup plied with the NiMH Battery Pack DO NOT completely discharge a rechargeable battery Rechargeable batteries must not be used for more than four 4 hours at a time Failure to follow this cau tion can result in reduced airflow and can cause the battery to be permanently damaged Installing the Green Battery Cap Assembly for NiMH Battery Packs only 1 Remove ...

Page 10: ...t the canister type is appropriate for use in the environment 1 Verify shelf life expiration date on carton bag and canister label has not been exceeded DO NOT use an expired canister DO NOT use the canister if the bag is opened damaged or missing The canister must be in its original packaging prior to use in a contaminated environment Do not reuse the canister Failure to follow this warning can r...

Page 11: ...THE BREATHING TUBE The FireHawk M7 Responder PAPR utilizes a 6 PAPR breathing tube extension coupled with either an 18 or 22 APR breathing tube Attaching the Breathing Tube assembly to the Blower 1 Remove the green plug from the PAPR breathing tube extension inlet Do not discard the plug The plug will be used when storing the breathing tube 2 Inspect the gray gasket in the breathing tube inlet If ...

Page 12: ...de of the cover twist and pull the spark cover off 6 Check the spark cover before each use to ensure no sparks have created holes or warped the part If holes are created or the part is warped replace the spark cover with a new one The FireHawk M7 Responder PAPR is now ready for use The user must follow the donning procedures before actu al use of the respirator 12 TAL 804 L Rev 0 10086003 motion f...

Page 13: ...ube to create or remove slack in the breathing tube Note The C420 PAPR may be used with either a standard 18 P N 10082517 or a long 22 P N 10082542 APR breathing tube Note Use a buddy if the situation permits to ensure that the C420 PAPR is donned correctly the head harness is in place the blower is positioned correctly the waist belt is secure and all components are properly assembled and tighten...

Page 14: ...test after four 4 hours of use and again two 2 hours later after six 6 hours of use Conducting an In Use Flow Test Note The user must leave the contaminated area and if necessary be decontaminated 1 Remove the breathing tube from the blower 2 Install the airflow indicator Refer to the Air Flow Test with Canisters Installed section 3 Turn the blower assembly switch to the ON position Ensure the red...

Page 15: ...anisters Canisters are considered to be in service when they are removed from their packaging Canisters are intended for one time use only and must be disposed of upon termination of use 1 Open the battery compartment by unthreading counter clockwise the battery cap assembly 2 Remove the battery a The non rechargeable LI SO2 battery must be dis posed of on termination of use Do not reuse the batte...

Page 16: ...NOTES 16 TAL 804 L Rev 0 10086003 ...

Page 17: ...r or chemical canisters 5 Inspect the equipment for worn inlet gaskets dam aged threads cracked plastic components rubber parts worn or frayed belts or other damaged compo nents Make note of any damaged components and replace before storage 6 Use a damp cloth or sponge saturated with Confidence Plus or equivalent cleaning solution to wipe the breathing tube and motor blower clean 7 Carefully clean...

Page 18: ...NOTES 18 TAL 804 L Rev 0 10086003 ...

Page 19: ...r discharge cycles for optimum battery performance The discharge cycles should be completed with the blower running in a non hazardous environment with no breathing tube or canisters attached to the blower 1 Place the charger horizontally on a flat surface and in a dust free area with a temperature range between 32 F and 100 F 0 C and 37 7 C The ideal tempera ture is 70 F 21 1 C 2 Insert the appro...

Page 20: ... to the charging plug housing Rapid Charger LED Illumination Sequence DO NOT allow the battery pack to fully discharge The functional system operational time for the battery pack is approx 4 hours Operating the system in excess of 4 hours results in significantly reduced air flow 20 TAL 804 L Rev 0 10086003 LED Illumination Charging Status w AC Power Cord plugged in Orange No battery attached or c...

Page 21: ...label from the side of the battery next to the contact end Attached to the label is a pull tab The pull tab must be removed with the label 2 Store the battery with the label removed for five 5 days to completely discharge 3 Dispose and or recycle batteries in accordance with federal state and local regulations DO NOT attempt to the charge the LI SO2 battery The battery may ignite resulting in seri...

Page 22: ...NOTES 22 TAL 804 L Rev 0 10086003 ...

Page 23: ...ative of MSA may bind MSA to any affirmation representation or modification of the war ranty concerning the goods sold under this contract THIS WARRANTY IS IN LIEU OF ALL OTHER WAR RANTIES EXPRESS IMPLIED OR STATUTORY AND IS STRICTLY LIMITED TO THE TERMS HEREOF MSA SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTIC ULAR PURPOSE 2 Exclusive Remedy It is expressly agre...

Page 24: ......