5. Leave area immediately if:

a. Breathing becomes difficult;
b. Dizziness or other distress occurs;
c. You taste or smell contaminant;
d. You experience eye, nose or throat irritation.

6. Use strictly in accordance with instructions, labels and limitations pertain-

ing to this device.

7. This respirator may not provide a satisfactory seal with certain facial char-

acteristics, such as beards or large sideburns, that prevent direct contact
between the skin and the sealing surface of the facepiece. Do not use this
facepiece if such conditions exist.

8. Never alter or modify this device.
9. This respirator is for use by trained and qualified personnel only.
10. Do not use for firefighting.
11. Do not use as an underwater device.
12. Thoroughly check out the apparatus on receipt prior to use.
13. The air delivered to the air supply hose of this device must be respirable

and of a purity equal to at least Grade D Gaseous Air of Compressed Gas
Association Commodity Specification for Air. G-7.1.

14. Do not use compressed oxygen with this device.
15. Use only the listed hose lengths and air pressure range.

Failure  to  follow  these  precautions  can  result  in  serious  personal  injury  or
death.

APPLICATION and OPERATING PRINCIPLE

The  Duo-Flo  Respirator  is  a  combination  air  supplied  respirator  and  air  purifying
respirator. It is approved by NIOSH for use with either a particulate filter or a chin
style  gas  mask  canister  for  respiratory  protection  against  specific  contaminants.
See the Approval Matrix for specific protection provided.

The air supplied mode of operation enables the user to work for long periods of time
in contaminated atmospheres without depleting the filter or canister. The air purify-
ing  mode  of  operation  can  be  used  for  entry,  egress,  and  moving  from  station  to
station in a contaminated atmosphere. It can also be used for continuous use when
an air supply is not available. The Duo-Flo Respirator is not for use in atmospheres
containing  less  than  19.5  percent  oxygen.  Also,  the  Duo-Flo  Respirator  is  not  for
entry into immediately dangerous to life or health (IDLH) atmospheres.

Constant Flow Type (Advantage

®

4000, Ultravue

®

, and Ultra Elite

®

Facepieces)

—  During  use,  the  air  supplied  mode  of  operation  prevails  as  long  as  the  user  is
connected  to  an  air  source.  The  air  purifying  mode  of  operation  is  entered  auto-
matically if the air-line is disconnected or if the air source is lost for any reason.

Pressure Demand Type (Ultravue and Ultra Elite Facepieces)

— During use, the

D/PD exhalation valve must be in the FILTER/CANISTER position when using the
respirator in the air purifying mode of operation. When the air-line is connected, the

TAL 7012 (L) Rev. 2 - 818369

3

Summary of Contents for Duo-Flo

Page 1: ...r repair call 1 800 MSA 2222 during regular work ing hours This manual including the warnings and cautions inside must be read and followed carefully by all persons who use or maintain this product in...

Page 2: ...L Follow the manufacturer s User Instructions for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accor dance with MSHA OSHA and other ap...

Page 3: ...r is a combination air supplied respirator and air purifying respirator It is approved by NIOSH for use with either a particulate filter or a chin style gas mask canister for respiratory protection ag...

Page 4: ...er to practice switching the valve from one position to the other Respirator Use Limitations The wearer must comply with the following MSA respirator use limitations 1 Maximum Use Concentration Do not...

Page 5: ...sed except for escape Time Use Limitation Canisters with an N95 filter shall be limited to 8 hours of use continuous or inter mittent against particulates Service time can be extended by performing an...

Page 6: ...itative fit test is used a fit factor that is at least 1 000 for a full facepiece respirator and 100 for a half mask respirator shall be obtained before that respira tor is assigned to an individual Q...

Page 7: ...ply section 4 Assemble apparatus as follows a Connect filter cartridge or canister to coupling nut on Duo Flo adapter check valve b Attach breathing tube between Duo Flo adapter tee and facepiece 5 Do...

Page 8: ...y moving adjustment slides to length en or shorten straps Adjust the straps just snug enough so that no air leaks around the facepiece It is not necessary to pull the straps so tight that the the resp...

Page 9: ...l No 7 665 1 Part No 455021 Hose Neoprene 25 ft Brass Model No 7 665 1 Part No 455022 Hose Neoprene 50 ft Brass Model No 7 665 1 Part No 471511 Hose PVC 15 ft Brass Model No 7 664 1 Part No 471512 Hos...

Page 10: ...d then dry None of the metal plastic rubber leather cloth or glass parts will be adversely affected by the cleaning solution Cleaning and Disinfecting at or below 110 F will avoid possible overheating...

Page 11: ...all instructions and warnings per taining to the respirator 2 The respirator and conditions meet the requirements outlined 3 The canister is the proper type for the contaminant or contaminants presen...

Page 12: ...Rev 2 818369 Duo Flo Constant Flow Respirator Assemblies Chin Canister Type FACEPIECE SEE PAGES 17 18 56651 BREATHING TUBE ASS Y ALTERNATE 57156 BREATHING TUBE ASS Y DUO FLOW AIR LINE ADAPTER ASSEMBL...

Page 13: ...5 480031 Snap Tite AL Locking TAL 7012 L Rev 2 818369 13 PLUG SEE PAGE 13 DUST COVER P N FITTING TYPE 486289 SCHRADER FOSTER STEEL 634450 SNAPTITE CEJN 634687 FOSTER BRASS HANSEN SST 634686 HANSEN BRA...

Page 14: ...14 TAL 7012 L Rev 2 818369 Duo Flo Constant Flow Quick Disconnects for Flow Control Devices...

Page 15: ...TAL 7012 L Rev 2 818369 15 FACEPIECE SEE PAGES 17 18 456651 BREATHING TUBE ASS Y 457158 BREATHING TUBE ASS Y ALTERNATE CHIN CARTRIDGE TYPE Duo Flo Constant Flow Respirator Assemblies...

Page 16: ...ket Part No Part No Type 481934 481871 Snap Tite AL 481937 481873 Snap Tite Brass 481938 481874 Snap Tite SST 481935 481870 Foster Steel 481936 481872 Foster Brass 481940 481876 Hansen Brass 481939 48...

Page 17: ...TAL 7012 L Rev 2 818369 17 Duo Flo Pressure Demand Quick Disconnects for Flow Control Devices...

Page 18: ...471224 471225 480251 480252 480253 480254 MEDIUM MODEL 7 203 1 SPEAKING RUBBER DIAPHRAGM NOSECUP PART Black Black Green NUMBER Hycar Silicone Hycar With Less With Less 457126 471209 471212 471213 463...

Page 19: ...IUM MODEL 7 753 1 SPEAKING RUBBER DIAPHRAGM NOSECUP PART Black Black Green NUMBER Hycar Silicone Hycar With Less With Less 484562 484563 484564 484565 484566 484567 484568 484569 484575 484576 484577...

Page 20: ...20 TAL 7012 L Rev 2 818369...

Page 21: ...TAL 7012 L Rev 2 818369 21...

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: