background image

REMOVING THE RESPIRATOR

Return to an uncontaminated area before removing the respirator. Check that
the respirator and your clothing are free from contaminant before removing the
respirator.

To remove the facepiece

1. Push the straps’ buckles forward to loosen and fully extend the bottom

straps.

2. Insert thumbs under the harness straps. Pull it up and away from face.

CLEANING AND DISINFECTING

The facepiece assembly (with canister removed) should be cleaned and disin-
fected after each use. MSA recommends using Confidence Plus™ Cleaning
Solution. Refer to the label of the cleaning solution for use instructions. A solu-
tion as effective as Confidence Plus™ Cleaning Solution and compatible with
MSA respirator components may be substituted. Rinse thoroughly in plain
warm water (110ºF to avoid possible overheating and distortion of parts) and
then air dry. ANSI suggests that users should be trained in cleaning procedure.

Alcohol should not be used as a germicide because it may deteriorate rub-
ber parts.

If not rinsed thoroughly, cleaning agent residue may irritate the wearer’s
skin.

Do not force-dry the parts by placing them in a heater or direct sunlight.
This will cause the rubber to deteriorate.

Cleaning and Disinfecting at or below 110°F temperature will avoid possi-
ble overheating and distortion of parts which would require replacement.

MAINTENANCE

This respirator must be kept in good condition to function properly. When any
respirator shows evidence of excessive wear or damage, it must be replaced
immediately. Refer to the Preparations for Donning section for proper inspec-
tion of the respirator. This respirator, when not in use, should be stored in its
storage bag or container and in a clean dry location. Do not distort the face-
piece during storage. When disposing of the respirator or its components, do
so in accordance with local, state and federal regulations.

CAUTION

!

CAUTION

!

CAUTION

!

CAUTION

!

TAL 8001 (L) Rev. 10 - 814175

9

Summary of Contents for advantage 1000

Page 1: ...1 800 MSA 2222 during regular working hours TAL 8001 L Rev 10 MSA 2008 Prnt Spec 10000005389 F Mat 814175 Doc 814175 This manual including the warnings and cautions inside must be read and followed ca...

Page 2: ...e or explosive atmospheres by MSHA NIOSH J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s Users Instructions for changing cartridges and...

Page 3: ...ined in the applicable NIOSH approval 3 For respirators with class P filters Replace filters when excessive breath ing resistance occurs while inhaling 4 For respirators with chemical canisters a User...

Page 4: ...Chemical Agents or Biological Agents is pos sible but not expected or for escape from possible CBA contamination and controlled low level CBA atmospheres which do not exceed the maximum use concentra...

Page 5: ...nce the user leaves the contaminated area he should enter the decontaminated area and follow the set decon procedure Failure to follow an acceptable decon procedure could lead to serious injury or dea...

Page 6: ...S CANISTER S See separate insert for NIOSH Approval Information P N 818082 PREPARATIONS FOR USE The following inspection points must be checked before donning the gas mask A mask that fails the inspec...

Page 7: ...arness straps Grip the straps by inserting thumbs through the straps Insert chin well into the lower part of facepiece then pull the harness back over head 2 Pull the back of the harness downward towa...

Page 8: ...ll remain while the breath is held unless there is a leak in the seal If any leakage is detected around the facial seal readjust head harness straps and repeat the test until there is no leakage If ot...

Page 9: ...hat users should be trained in cleaning procedure Alcohol should not be used as a germicide because it may deteriorate rub ber parts If not rinsed thoroughly cleaning agent residue may irritate the we...

Page 10: ...use It is normal for this wax to come to the surface and can be cleaned by using MSA Confidence Plus P N 10009971 Rubber surface imperfections may be observed upon closer inspection of the mask and a...

Page 11: ...TAL 8001 L Rev 10 814175 11...

Page 12: ...12 TAL 8001 L Rev 10 814175...

Reviews: