Storage, Maintenance and Disposal
MSA
GB
4
Storage, Maintenance and Disposal
4.1
Half mask
Maintenance and Tests
1
Only random sample of units that are stored airtight
Recordings of inspections and valve dish replacements are recommended.
Attention!
For disposal of filters applicable National Regulations must be observed.
Cleaning and Care:
Clean and disinfect mask after every use. To clean the mask remove the
filters [cleaning the filters is not possible]. Inhalation and exhalation
valves are cleaned seperately and reassembled only after drying.
Use a mild detergent [e.g. Disinfectant AUER 90, Part No. D2055765] in
lukewarm water and rinse with clear water and dry air [max. 50°C].
Spare parts:
For a list of available spare parts see chapter 5.2.
Storage:
Only undamaged mask must be stored for further use. When not in use,
store respiratory protective device in cool, dry and clean ambient air.
Shelf life:
The manufacturing date of the mask is marked inside.
For an example see chapter 6.
Operations required on mask
Intervals
Before use
After use
Semi
anually
Every
2 years
Cleaning and disinfection
X
X
1
Function test
X
X
1
X
Exhalation Valve disc replacement
X
Leak test Excess and/or
negative pressure, check by user
X