RECONDITIONING AFTER USE
At
the end of an exercise the training unit MSA AUER SSR 30/100 TR must
be cleaned, disinfected, dried, repacked and lead sealed.
This includes the following work:
5.1 Disassembly
Fig. 10
Unscrew breathing tube with
connecting piece from can-
ister.
Fig. 11
Remove connecting piece
from breathing tube.
Note
If necessary press out
check valve from inside
(use suitable tool, but not a
screw driver) and fit new
valve (valve disc must be
positioned outside).