MS Sedco DH400 Installation Instructions Manual Download Page 3

 

Direction Detection:

  When set to ON, pedestrians

 

moving away from the sensor will NOT be detected.

 

NOTE:

  For pedestrian safety purposes when 

 

“Doorway Learn” is set to ON, the 1st and 2nd row

 

of detection will detect pedestrians regardless of 

 

direction of movement. 

 

 

Doorway Learn:

  Allows the 1st row of detection to 

 

be focused inside the door close area without 

 

detecting the door movement.

 

NOTE:

  When “Doorway Learn” is turned ON, the 

 

sensitivity level of the 1st row of detection is at 

 

maximum only when the outer rows of detection 

 

are activated. 

 

Section 6

Power & “Doorway Learn” Setting

BEFORE APPLYING POWER, READ AND FOLLOW THESE 

INSTRUCTIONS:

When power is applied, the sensor will read and store the 

environmental optical parameters.  This is necessary for 

Presence Detection to work properly. 

1.  CLEAR THE AREA OF ANY UNNECESSARY OBJECTS.

2.  Apply POWER.

3.  Vacate the Detection Pattern immediately.  While the 

 

sensor sees ANY moving objects in its DETECTION 

 

PATTERN, it will not proceed to the following step.

4.  DO NOT enter DETECTION PATTERN for 10 seconds 

 

(Presence Detection Setting).

5.  TEST the presence feature, especially near the door.

When carrying out the following work, TURN OFF THE 

POWER:

1.  When the floor conditions change.

2.  Adjusting pattern or sensitivity.

“DOORWAY LEARN” is OFF 

(Ref. Sec. 5-Dip Switch Settings)

•  Upon power ON, the solid Green LED turns on

 

indicating that the sensor is in standby mode and

 

ready to detect.

“Doorway Learn” is OFF 

(Cont.)

Presence Detection:  It takes 10 seconds after the sensor 

powers up for presence detection to be initiated on all 

rows of detection.  If someone enters the detection area 

before 10 seconds has elapsed, the sensor will continue 

to initialize until after 5 seconds with no motion being

detected.

“DOORWAY LEARN” is ON

(Ref. Sec. 5-Dip Switch Settings)

•  Upon power ON, the Red LED indicates a door open

 

relay output to begin the “Doorway Learn” process.

•  Green LED blinks for 37 seconds while the “Doorway 

 

Learn” process is carried out.  Door opens/closes.

Page 3

DH400v1214

High Mount Active Infrared Presence Detector for Automatic Door Control 

INSTALLATION INSTRUCTIONS

DH400

8701 Castle Park Drive 

 Indianapolis, Indiana 46256

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Green solid LED

Red solid LED

Green blinking LED

Green blinking LED

Summary of Contents for DH400

Page 1: ...ngine cover 3 Do not leave any objects which may move in the detection pattern 4 Do not mount in a humid or steamy environment 5 Do not mount where rain or snow will fall directly on unit 6 Do not mount where snow or water will accumulate on floor if possible 7 Do not mount in a place where reflection of sunlight will shine on unit 8 Use different frequency settings for sensor in close proximity T...

Page 2: ...ttern Width Right Side The right side detection area for approaching direction can be fixed by setting to 6 4 or 2 rows 6 Rows 4 Rows 2 Rows Installation Height Set to installation height required NOTE Set the sensitivity after setting the mounting height Refer to Section 8 Verification of Operation regarding the standard of sensitivity corresponding to mounting height Page 2 DH400v1214 DH400 High...

Page 3: ...econds Presence Detection Setting 5 TEST the presence feature especially near the door When carrying out the following work TURN OFF THE POWER 1 When the floor conditions change 2 Adjusting pattern or sensitivity DOORWAY LEARN is OFF Ref Sec 5 Dip Switch Settings Upon power ON the solid Green LED turns on indicating that the sensor is in standby mode and ready to detect Doorway Learn is OFF Cont P...

Page 4: ... Learn is turned ON the sensitivity level of the inner row of detection is at maximum ONLY when the outer rows of detection are activated CAUTION If you change dip switch setting or sensitivity volume the sensor will be reest During resetting indiator LED is blinking with orange color Keep away from detection area After resetting the sensor becomes the same state as it is turned Power on In case t...

Page 5: ...t operate properly recheck the dip switch settings and pattern adjustments 3 After rechecking if there is still a problem adjust the sensitivity Adjust high clockwise to increase sensitivity Adjust low counter clockwise to decrease sensitivity APPLY ONLY SMALL TORQUE Standard of sensitivity volume setting depending on Mounting Height Height Setting Setting Standard 6 6 2 0m 8 2 2 5m 4 8 2 2 5m 9 8...

Page 6: ...droplet on the sensor lens SOLUTION 3 Wipe sensor lens with clean cloth and install a weather cover if necessary CAUSE 4 Detection pattern is too far from the door detecting people passing by SOLUTION 4 Adjust detection pattern CAUSE 5 Detection area overlaps with that of another sensor SOLUTION 5 Ensure different frequency setting for each sensor CAUSE 6 Detection of falling snow insects leaves e...

Page 7: ...sions Section 13 Warranty MS SEDCO guarantees this product to be free from manufacturing defects for 3 years from date of installation Unless MS SEDCO is notified of the date of installation the warranty will be in effect for 3 years from the date of shipment from our factory If during the first 3 years our motion detector or support device fails to operate and has not been tampered with our abuse...

Page 8: ... dia 10mm O 39 2 Be sure to stick this mounting template with its bottom adjusted parallel to the same position as the bottom edge of E the engine cover E E f5 Mount within 50mm 1 97 above the bottom edge of the engine cover Bottom Position of Engine Cover Center l MOUNTING TEMPLATE I SP 10224 I E f5 ...