![MS Sedco 216 Installation Instructions Download Page 3](http://html.mh-extra.com/html/ms-sedco/216/216_installation-instructions_1846222003.webp)
216, 216-L, 216-N
Active Infrared "Touchless" Switch
INSTALLATION INSTRUCTIONS
Page 3
(82A023) 216v1014
FIGURE 1—Operating Modes Diagram
FIGURE 2—Wiring Diagram
1)
Standard "Fail Close" Mode (Factory Setting):
This is the most common operating mode. In this
mode, if power were to fail to the 216 series switch, the door it is activating will stay closed (the
switch relay is in its inactive state). The unit is shipped from the factory in this mode - no change
to the jumpers is necessary. Wire connections are COM and N.O.
2)
Optional "Fail Open" Mode (Cut Jumper 1):
In this mode, if power were to fail to the 216 series
switch, the door it is activating will open (the switch relay is in its active state). In order to program
this mode, cut Jumper 1. Wire connections are COM and N.C.
3)
Toggle Mode:
In this mode, when the 216 series switch is activated, the relay is energized and
maintains that state until it is activated again, returning the relay to its de-energized state. For
example, a 216 series switch could be located at the entrance of a room. When a person enters,
the 216 series switch turns on the light. As they exit, the 216 series switch turns off the light. In
order to program this mode, cut Jumper 2. Wire connections are COM and N.O.
Input Connections
Output Connections
12-24V AC or DC
Green = Common (COM)
Red and black wires have no polarity on this product.
Blue = Normally Open (N.O.)
Do not tie either of the power supply lines to ground.
Violet = Normally Closed (N.C.)
The power in must “float” and not be grounded.
Fail Close Mode (Factory Setting):
Wire connections COM & N.O.
Fail Open Mode:
Cut Jumper 1; wire connections COM & N.C.
Toggle Mode:
Cut Jumper 2; wire connections COM & N.O.
WIRING
INPUT
OUTPUT
2 RED
GRN = COM
12-24V AC/DC
BLU = N.O.
NO POLARITY
VIO = N.C.
JP1
JP2
CUT FAIL OPEN
TOGGLE
MODE
MODE
IN FAIL CLOSE
DELAY
MODE
MODE
JP1
JP2
SIDE VIEW
Jumper 1 = JP1
Jumper 2 = JP2
JP1
JP2
Cut here with knife
!
8701 Castle Park Drive
Indianapolis, Indiana 46256
Telephone: (317) 842-2545