MRU GmbH USER MANUAL MFplus Part 2 OPTION TRGI
27
3.4.6.6
Adaption phase
The adaption phase can be shortened at any time using the F1 button.
With F3 the temperature curve will be displayed.
Once the adaption phase is completed the stress test will start
automatically.
3.4.6.7
Test phase
Now the usage capability test is in operation. Also here F3 will make
the temperature curve visible.
The temperature curve will help judging the test result. A decreasing
temperature during the test phase can result in a low pressure drop.
There is no automatic pressure/temperature compensation!
3.4.6.8
View results
At the end of the test the start pressure, end pressure and the resulting
leakage rate will be displayed.
With the F2 button the results can be saved.
With ESC you will return to the measuring menu.