4.2.

 

Spillage test on flue gas systems 

The change sensor RM400 is used for locating leaks in flue gas pipes. 

Before measuring, remove the protective cap from the interchangeable sensor! 

Slowly guide the sensor along the points to be tested. If there is a leak, the meas-

ured value changes and the flashing frequency of the red LED in the sensor foot in-

creases with the increase in moisture on the sensor surface. 
 

For measurement, the sensor surface must be dry and at room temperature. 

 

Functions in the Context menu:

 

function 

explanation 

Signal ON  (Key F1) 

With this function the signal is switched on.  

Signal ON (Key F1) 

With this function the signal is switched off. 

Max = 0 (Key F3) 

The value Max is set to zero. 

Reset 

This function resets the graphic. 

Measurement menu 

(ESC) 

Exit measuring program 

Info 

The information (sensor name, serial number, firmware 

version) about the sensor is displayed here.   

 

Technical Specification: 

 

range 

resolution 

response time 

Sensor RM400

 

0 … 100 

< 1 Sec. 

 

 

NOTE

 

The RM400 operates on a conductive sensor surface, so do not 
clean with alcohol or distilled water. 
If necessary, clean the sensor surface with saline water and al-
low it to dry 

 

 

DANGER

 

Danger due to improper use 

Non-compliance with the measurement rules can result in fatal 

accidents. 
The meter may only be used for advertising purposes to locate 

gas leaks in the installation area. 

 

 
 

 

Summary of Contents for 400DH

Page 1: ...USER MANUAL 400DH MRU GmbH D 74172 Neckarsulm 1 14...

Page 2: ...manual 2019 by MRU No part of this manual may be published in any form print photocopy elec tronic media or any other publication form without a written approval by the publisher All user trademarks...

Page 3: ...manual 6 3 Description 7 3 1 The hand detector probe 400DH 7 3 2 Terms and window designation 8 3 3 Context menu 8 4 Interchangeable sensors with technical specs 9 4 1 Leak detection on gas installat...

Page 4: ...e able to read instructions as needed 1 1 Intended Usage The hand detector probe 400DH cannot be used for personal protection or con tinuous monitoring tasks The hand detector probe 400DH is available...

Page 5: ...cing and marketing high quality emission monitoring analyzers MRU GmbH manufactures a wide range of instruments from standard analyzers up to tailor made industrial analyzers Plant 1 Sales Service R D...

Page 6: ...ions 2 2 Safety manual The used categories of safety precautions are here explained once more DANGER Identifies an immediate impending hazard that if ignored will result in severe bodily injuries or d...

Page 7: ...match Select the menu item 400DH ext probe in the measuring device Connect sensor is displayed The hand detector probe 400DH alone does not support measurement Each measurement function is implemente...

Page 8: ...ion explanation Signal ON Key F1 If the sensor has a signal threshold signal ON appears in the context menu and on the display Key F1 With this function the signal is switched on Signal OFF Key F1 If...

Page 9: ...he sensor is zeroed Max 0 Key F3 The value Max is set to zero Setting Setting units and Signal thresholds Printout Dr Printout is generated a printer is required for this function Meas menu ESC Exit m...

Page 10: ...With this function the signal is switched on Signal ON Key F1 With this function the signal is switched off Max 0 Key F3 The value Max is set to zero Reset This function resets the graphic Measuremen...

Page 11: ...to zero Setting Setting units Printout Dr Printout is generated a printer is required for this function Meas menu ESC Exit measuring program Info The information sensor name page number firmware vers...

Page 12: ...menu function explanation Signal ON Key F1 With this function the signal is switched on Signal ON Key F1 With this function the signal is switched off Max 0 Key F3 The value Max is set to zero Reset T...

Page 13: ...nction the signal is switched off Zero point Key F2 With this function the sensor is zeroed Max 0 Key F3 The value Max is set to zero Reset This function resets the graphic Setting Setting units and s...

Page 14: ...USER MANUAL 400DH 14 14 MRU GmbH D 74172 Neckarsulm 5 Declaration of conformity...

Reviews: