MrHeater MHVFBF10NGT Operating Instructions And Owner'S Manual Download Page 13

13

Operating Instructions and Owner’s Manual

Mr. Heater | Unvented Natural Gas Fired Room Heater

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

TR

OUBLESHOO

TING

SYMPTOM

SYMPTOM

• 

ODS/pilot lights but flame goes out when control knob is released.

• 

Burner backfiring during operation.

CAUSE

CAUSE

REMEDY

REMEDY

1. Gas supply turned off or equipment shutoff 

valve closed.

1. Turn on gas supply or open equipment shutoff valve.

2. Control knob not fully pressed in while pressing 

ignition button.

2. Press in control knob fully while pressing ignition button.

3. Air in gas line when installed.

3. Continue holding down control knob. Repeat ignition operation until 

air is removed.

4. ODS/Pilot is clogged.

1. Clean ODS/Pilot (see “CLEANING AND MAINTENANCE” on page 11).

5. Control knob not in pilot position.

5. Turn control knob to pilot position.

6.  Gas regulator setting is not correct.

6. Replace gas regulator.

7. Thermocouple connection loose at control 

valve.

7. Hand tighten thermocouple nut until snug, and then tighten 1/4 

turn more.

8. Pilot flame not touching thermocouple, which 

allows thermocouple to cool, causing pilot 
flame to go out. This problem could be caused 
by one or both of the following:

a. Low gas Pressure
b. Dirty or Partially clogged ODS/pilot

a. Contact local gas company.
b. Clean ODS/pilot (see Cleaning and Maintenance, page 11).

9. Thermocouple damaged.

9. Replace thermocouple.

10. Control Valve damaged.

10. Replace control valve.

1. Burner orifice is clogged or damaged.

1. Clean burner orifice (see Cleaning and Maintenance on 

page 11), or replace burner orifice.

2. Burner damaged.

2. Replace burner.

3. Gas regulator defective.

3. Replace gas regulator.

REMEDY

SYMPTOM

• 

Burner plaque(s) does not glow [Infrared Only].

CAUSE

1. Plaque damaged.

1. Replace burner.

2. Control knob set between locked positions.

2. Turn control knob until it locks at desired setting.

3. Inlet gas pressure is too low.

3. Replace gas regulator.

REMEDY

SYMPTOM

• 

Slight smoke or odor during initial operation.

CAUSE

1. Residues from manufacturing process.

1. Problem will stop after a few hours of operation.

Summary of Contents for MHVFBF10NGT

Page 1: ...e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch...

Page 2: ...rating the heater Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Page 3: ...been underwater Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been underwater 9 Operating heat...

Page 4: ...lings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and 2 Weather stripping has...

Page 5: ...onfined space You will need no additional fresh air ventilation Ventilation Air Ventilation from Inside Building This fresh air would come from an adjoining unconfined space When ventilation to an adj...

Page 6: ...s are 16 inches apart Attach mounting bracket to wall in one of two following ways 1 Attach to wall studs 2 Attach to wall anchor Decide which way best suits your needs Either method will provide a se...

Page 7: ...rk screws locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting screw into hollow or solid wall install wall anchors Follow steps 1 through 4 under Attaching to Wall...

Page 8: ...pliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ps...

Page 9: ...ctly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Shut...

Page 10: ...ilot Position CAUTION Do not try to adjust heating level by using equipment shutoff valve To Turn Off Gas To Appliance SHUTTING OFF HEATER 1 Turn off equipment shutoff valve 2 Turn control knob clockw...

Page 11: ...s vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We...

Page 12: ...l the fire department SYMPTOM SYMPTOM When ignitor button is pressed in there is a spark at the ODS pilot but no ignition When igniter button is pressed in there is no spark at pilot CAUSE CAUSE REMED...

Page 13: ...as regulator 7 Thermocouple connection loose at control valve 7 Hand tighten thermocouple nut until snug and then tighten 1 4 turn more 8 Pilot flame not touching thermocouple which allows thermocoupl...

Page 14: ...lly clogged 3 Clean ODS pilot see Cleaning and Maintenance page 11 1 Gas leak See WARNING statement at top of page 12 1 Locate and correct all leaks see Checking Gas Connections page 9 2 Control valve...

Page 15: ...o Fresh Air for Combustion and Ventilation on pages 3 5 REMEDY SYMPTOM Heater produces a clicking ticking noise just after burner is lit or shut off CAUSE 1 Metal expanding while heating or contractin...

Page 16: ...01 Orifice 1 9 80084 Regulator 1 10 80055 Regulator Mounting Bracket 1 11 80058 Floor Mounting Feet Beige 1 Item Part No Description 80214 Floor Mounting Feet White 1 12 NA Regulator Connection 1 13 8...

Page 17: ...84 Regulator 1 7 80055 Regulator Mounting Bracket 1 8 80058 Floor Mounting Feet Beige 1 80214 Floor Mounting Feet White 1 Item Part No Description 9 NA Regulator Connection 1 10 80036 Wall Mounting Br...

Page 18: ...Natual Gas Fired Room Heater Operating Instructions and Owner s Manual NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Page 19: ...ons and Owner s Manual Mr Heater Unvented Natural Gas Fired Room Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Page 20: ...AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessorie...

Reviews: