MrHeater MHVFBF10NGT Operating Instructions And Owner'S Manual Download Page 1

Plaque Heaters 

MHVFRD10NGT

Blue Flame Heaters

MHVFBF10NGT

OPERATING INSTRUCTIONS AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions 

in a safe place for future reference. Do not allow anyone who has not read these 

instructions to assemble, light, adjust or operate the heater.

www.mrheater.com

800-251-0001

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Model # MHVFRD10NGT

 

            MHVFBF10NGT

UNVENTED  

NATURAL GAS FIRED 

ROOM HEATER

  WARNING: If the information in this manual is not followed exactly, a fire or explosion 
may result causing property damage, personal injury, or loss of life. 

 

-

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 
any other appliance.

 

-

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your building.
•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.

 

-

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to 
Fresh Air for Combustion and Ventilation section on page 4 of this manual. 

This appliance may be installed in an aftermarket permanently manufactured (mobile) home, 
where not prohibited by local codes. 
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with any other gas.

Summary of Contents for MHVFBF10NGT

Page 1: ...e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch...

Page 2: ...rating the heater Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Page 3: ...been underwater Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been underwater 9 Operating heat...

Page 4: ...lings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and 2 Weather stripping has...

Page 5: ...onfined space You will need no additional fresh air ventilation Ventilation Air Ventilation from Inside Building This fresh air would come from an adjoining unconfined space When ventilation to an adj...

Page 6: ...s are 16 inches apart Attach mounting bracket to wall in one of two following ways 1 Attach to wall studs 2 Attach to wall anchor Decide which way best suits your needs Either method will provide a se...

Page 7: ...rk screws locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting screw into hollow or solid wall install wall anchors Follow steps 1 through 4 under Attaching to Wall...

Page 8: ...pliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ps...

Page 9: ...ctly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Shut...

Page 10: ...ilot Position CAUTION Do not try to adjust heating level by using equipment shutoff valve To Turn Off Gas To Appliance SHUTTING OFF HEATER 1 Turn off equipment shutoff valve 2 Turn control knob clockw...

Page 11: ...s vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We...

Page 12: ...l the fire department SYMPTOM SYMPTOM When ignitor button is pressed in there is a spark at the ODS pilot but no ignition When igniter button is pressed in there is no spark at pilot CAUSE CAUSE REMED...

Page 13: ...as regulator 7 Thermocouple connection loose at control valve 7 Hand tighten thermocouple nut until snug and then tighten 1 4 turn more 8 Pilot flame not touching thermocouple which allows thermocoupl...

Page 14: ...lly clogged 3 Clean ODS pilot see Cleaning and Maintenance page 11 1 Gas leak See WARNING statement at top of page 12 1 Locate and correct all leaks see Checking Gas Connections page 9 2 Control valve...

Page 15: ...o Fresh Air for Combustion and Ventilation on pages 3 5 REMEDY SYMPTOM Heater produces a clicking ticking noise just after burner is lit or shut off CAUSE 1 Metal expanding while heating or contractin...

Page 16: ...01 Orifice 1 9 80084 Regulator 1 10 80055 Regulator Mounting Bracket 1 11 80058 Floor Mounting Feet Beige 1 Item Part No Description 80214 Floor Mounting Feet White 1 12 NA Regulator Connection 1 13 8...

Page 17: ...84 Regulator 1 7 80055 Regulator Mounting Bracket 1 8 80058 Floor Mounting Feet Beige 1 80214 Floor Mounting Feet White 1 Item Part No Description 9 NA Regulator Connection 1 10 80036 Wall Mounting Br...

Page 18: ...Natual Gas Fired Room Heater Operating Instructions and Owner s Manual NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Page 19: ...ons and Owner s Manual Mr Heater Unvented Natural Gas Fired Room Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Page 20: ...AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessorie...

Reviews: