T: +1-613-545-0466 www.mrel.com [email protected]
3
1.3 Definitions of VOD Settings
This section will discuss the meaning of each setting.
Trigger Level
is the threshold that the signal will cross to indicate a valid trigger. For
VOD
, the typical setting for
Trigger Level
is 95%.
Pre-Trigger Time
is the amount of time of the
Total Time
available for each test that will be captured prior to the trigger point. For VOD, the typical
setting for
Pre-Trigger Time
is 25%
Number of Tests
is a number from 1 to 16 that the total memory of the unit is divided into. The lower the
Number of Tests
, the larger number of
points will be recorded per test. The user needs to ensure that the amount of time is sufficient to capture the test which includes the amount of Pre-
Trigger Time
and the
Total Time
.
Recording Rate
is the number of points captured per second. The faster the
Recording Rate
, the shorter the amount of time within each test. For
VOD
, the typical setting for
Recording Rate
is 1 MHz or or 2 MHz.
External Trigger
is the setting that will allow the user to use an external source to have a valid trigger. There are two ways for the
MicroTrap™
VOD/Data Recorder
to receive an
External Trigger
.
• Make Circuit
uses a loop of wire that is normally open circuit and triggers the
MicroTrap™
when the circuit closes.
• Break Circuit
uses a loop of wire that is normally closed circuit and triggers the
MicroTrap™
when the circuit opens.
For more details on the
External Trigger
feature, refer to
Section 5.5
.
To use
External Trigger
, ensure that the switch on the panel has been set to
External
prior to pressing the
Start
button.
Summary of Contents for MicroTrap
Page 5: ...T 1 613 545 0466 www mrel com contact mrel com 1 Chapter 1 Getting Started...
Page 8: ...M i c r o T r a p O p e r a t i o n s M a n u a l E d i t i o n 4 4 4...
Page 9: ...T 1 613 545 0466 www mrel com contact mrel com 5 Chapter 2 Introduction...
Page 13: ...T 1 613 545 0466 www mrel com contact mrel com 9 Chapter 3 Hardware...
Page 40: ...M i c r o T r a p O p e r a t i o n s M a n u a l E d i t i o n 4 4 36...
Page 41: ...T 1 613 545 0466 www mrel com contact mrel com 37...
Page 42: ...M i c r o T r a p O p e r a t i o n s M a n u a l E d i t i o n 4 4 38...
Page 50: ...M i c r o T r a p O p e r a t i o n s M a n u a l E d i t i o n 4 4 46...
Page 55: ...T 1 613 545 0466 www mrel com contact mrel com 51...