10

Annex

Wiring Diagram

for reference only, users won’t be informed if there is modification for this diagram

Control Board

Power Switch

Input Power
AC 100

120V

50Hz/60Hz

Fuse
250V 3A Φ5X20

Position Sensor

Display Board

Heater

X Motor

Y Motor

Temperature Sensor

Summary of Contents for UT-1001

Page 1: ...Operation Manual UT 1001 Semi Automated Plate Sealer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 1 22...

Page 2: ...ent In order to use the instrument properly please read this manual carefully before using the instrument Opening Check Please check the instrument and appendix with the packing list when you first op...

Page 3: ...t the countermeasure according to them This product is a normal and an indoor instrument which conforms to Standard GB9706 1 Class I B type Before using the device read the manual carefully This unit...

Page 4: ...use and operating under improper condition also is not applicable for the damage which caused by repair and refit without authorization The instrument should be put in the place of low temperature lit...

Page 5: ...ERS AND CHARACTERISTICS 2 CHAPTER 3 BASIC INSTRUCTIONS 3 1 STRUCTURE OVERVIEW 3 2 OPERATION PANEL 4 3 DISPLAY 4 CHAPTER 4 OPERATION GUIDE 5 1 SEAL CONDITION SETTING 5 2 SEAL OPERATION 6 3 HEATING PLAT...

Page 6: ...9 to 48mm high 3 Adjustable Sealing Temperature 80 200 4 OLED display screen high light and no visual angle limit 5 Precise temperature timing and pressure for consistent sealing 6 Compact footprint o...

Page 7: ...e humidity 70 Power AC 100 120V 50Hz 60Hz 2 The basic parameters and characteristics Display OLED Temperature setting 80 200 Temperature accurate 1 Seal time 0 5s 10s increased by 0 1 seconds Cooling...

Page 8: ...ctions This chapter mainly introduces the structure operation keys and displays of the instrument as well as preparatory work before starting Please read this chapter before starting when uses this in...

Page 9: ...Semi Automated Plate Sealer Operation Manual Chapter 3 Basic Instructions 4 2 Operation panel 3 Display Drawer Key Seal Key Setting Key...

Page 10: ...decrease time and clockwise rotation to add time Time setting range is 0 5 10 seconds Remark It will confirm the values automatic after 5 seconds 1 3 Setting the pressure function Remark Adjust the pr...

Page 11: ...according to practical situation 2 Seal operation After setting up the seal condition seal operation as follows 2 1 Press PLATE In Out key and pull the drawer Then put in the standard plate adapter mi...

Page 12: ...heater plate caused by misuse and affect the instrument normal use then should clean the surface of heating plate according to following step 3 2 Press PLATE In Out key make the drawer out switch of t...

Page 13: ...etting temperature The unit will into Power down mode if there is no action on instrument more than 120 minutes Display screen will turn off power off heater supply and only a weak current supply to t...

Page 14: ...ocked Contact the supplier 5 Display Err405 and alarm Du sound The upper micro switch is broken Contact the supplier 6 Display Err412 The below photo electric switch is broken Contact the supplier 7 D...

Page 15: ...nnex Wiring Diagram for reference only users won t be informed if there is modification for this diagram Control Board Power Switch Input Power AC 100 120V 50Hz 60Hz Fuse 250V 3A 5X20 Position Sensor...

Reviews: