3. FRONT PANEL DESCRIPTION
3-1 Emissivity Button3-2 Down Button3-3 LCD Display3-4 Up Button3-5 Mode Button3-6 Measure Switch3-7 Battery Cover3-8 Infrared Lens3-9 Laser3-10 LED3-11 Thermocouple Socket
Fig. 1
4
Page 1: ...strument its durable structure developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERAT...
Page 2: ...tton 4 3 2 Down Button 4 3 3 LCD Display 4 3 4 Up Button 4 3 5 Mode Button 4 3 6 Measure Switch 4 3 7 Battery Cover 4 3 8 Infrared Lens 4 3 9 Laser 4 3 10 LED 4 3 11 Thermocouple Socket 4 4 MEASURING...
Page 3: ...ock mode Last measurement memory Hi Lo Temperature Audio Alarm Laser target and Back light On Off control Adjustable emissivity value from 0 1 to 1 00 Preset emissivity value at 0 95 Power supply by t...
Page 4: ...1 1 000 1 000 1 1 1 000 1 000 Circuit Exclusive microcomputer circuit Emissivity Adjustment range 0 10 to 1 00 Adjustment step 0 01 0 95 default emissivity value Infrared Temp Thermocouple pie Temp Se...
Page 5: ...5 mA with target light on Approx DC 29 5 mA Operating 0 to 50 32 to 122 Temperature Operating Less than 80 RH Humidity Weight 386 g 0 85 LB Dimension 203 x 197 x 47 mm 8 0 x 7 7 x 1 8 inch Standard O...
Page 6: ...PANEL DESCRIPTION 3 1 Emissivity Button 3 2 Down Button 3 3 LCD Display 3 4 Up Button 3 5 Mode Button 3 6 Measure Switch 3 7 Battery Cover 3 8 Infrared Lens 3 9 Laser 3 10 LED 3 11 Thermocouple Socket...
Page 7: ...e Spot is 50 1 The two laser points are the reference for the target spot size Please make sure the target area is within the field of view 3 Press Emissivity Button 3 1 Fig 1 for setting the emissivi...
Page 8: ...AL or Lo Alarm LAL then press Measure Button 3 6 Fig 1 to confirm it For example When the reading 26 9 LAL 27 the Low icon will flash and you will hear a beep sound Connect the thermocouple with Therm...
Page 9: ...1 for laser function ON OFF With flash light be turned on in the same time as laser 5 MEASURING CONSIDERATION 5 1 LCD error message The thermometer incorporates visual diagnostic messages as follows H...
Page 10: ...splayed when the temperature being measured is outside of the measurement range 6 BATTERY REPLACEMENT When the Low Battery icon indicates the battery is low the battery should be replaced immediately...
Page 11: ...for many general purpose application Thermocouple Measure Range 50 to 900 Probe 50 to 1650 Type K TP 02A Dimension 10cm tube 3 2mm Dia Thermocouple Measure Range 50 to 1200 Probe 50 to 2200 Type K TP...