MRC TM-969 Operation Manual Download Page 1

Your purchase of this INFRARED THERMOMETER marks a step

 

forward for 

you into the field of precision measurement.

 

Although this  METER is a 

complex and delicate instrument, its

 

durable structure developed. 

Please read the following

 

instructions carefully and always keep this 

manual within easy

 

reach.

       OPERATION MANUAL

 

PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 

3, Hagavish st. Israel 58817  Tel: 972 3 5595252, Fax: 972 3 5594529   

[email protected]

 

MRC.

1

.2

2

Dual laser + type K thermometer

1000  

 

INFRARED 

THERMOMETER

Model : TM-969

Summary of Contents for TM-969

Page 1: ...strument its durable structure developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERAT...

Page 2: ...tton 4 3 2 Down Button 4 3 3 LCD Display 4 3 4 Up Button 4 3 5 Mode Button 4 3 6 Measure Switch 4 3 7 Battery Cover 4 3 8 Infrared Lens 4 3 9 Laser 4 3 10 LED 4 3 11 Thermocouple Socket 4 4 MEASURING...

Page 3: ...ock mode Last measurement memory Hi Lo Temperature Audio Alarm Laser target and Back light On Off control Adjustable emissivity value from 0 1 to 1 00 Preset emissivity value at 0 95 Power supply by t...

Page 4: ...1 1 000 1 000 1 1 1 000 1 000 Circuit Exclusive microcomputer circuit Emissivity Adjustment range 0 10 to 1 00 Adjustment step 0 01 0 95 default emissivity value Infrared Temp Thermocouple pie Temp Se...

Page 5: ...5 mA with target light on Approx DC 29 5 mA Operating 0 to 50 32 to 122 Temperature Operating Less than 80 RH Humidity Weight 386 g 0 85 LB Dimension 203 x 197 x 47 mm 8 0 x 7 7 x 1 8 inch Standard O...

Page 6: ...PANEL DESCRIPTION 3 1 Emissivity Button 3 2 Down Button 3 3 LCD Display 3 4 Up Button 3 5 Mode Button 3 6 Measure Switch 3 7 Battery Cover 3 8 Infrared Lens 3 9 Laser 3 10 LED 3 11 Thermocouple Socket...

Page 7: ...e Spot is 50 1 The two laser points are the reference for the target spot size Please make sure the target area is within the field of view 3 Press Emissivity Button 3 1 Fig 1 for setting the emissivi...

Page 8: ...AL or Lo Alarm LAL then press Measure Button 3 6 Fig 1 to confirm it For example When the reading 26 9 LAL 27 the Low icon will flash and you will hear a beep sound Connect the thermocouple with Therm...

Page 9: ...1 for laser function ON OFF With flash light be turned on in the same time as laser 5 MEASURING CONSIDERATION 5 1 LCD error message The thermometer incorporates visual diagnostic messages as follows H...

Page 10: ...splayed when the temperature being measured is outside of the measurement range 6 BATTERY REPLACEMENT When the Low Battery icon indicates the battery is low the battery should be replaced immediately...

Page 11: ...for many general purpose application Thermocouple Measure Range 50 to 900 Probe 50 to 1650 Type K TP 02A Dimension 10cm tube 3 2mm Dia Thermocouple Measure Range 50 to 1200 Probe 50 to 2200 Type K TP...