background image

 

DCC DECODER-EQUIPPED LOCO OPERATION (DUAL MODE) 

 

Press the 

Mode

 button on the base unit to select “Dual Mode”. The red LED will 

be lit on the base unit. The LCD will display the current loco number and its 

speed. For example, Loc3, 000 means that the current loco is #3 and its speed  

is 0. You will have to program decoder equipped locos with different addresses in 

order to operate multiple locos. 

 

PROGRAMMING (DUAL MODE) 

Place one loco on the track 

Only have one loco on the track during 

programming

. Press 

P

 (

all of the buttons mentioned here are the buttons 

on the walkaround

). It will prompt with 

Loc_ Adr

. Select a number from #1 

to #6 for this loco. You cannot use a number larger than 6. Press the 

number you have selected and then press 

Enter

. It will send the command 

to assign the loco with the number you have selected. This is now the loco 

address. 
Next, it will prompt with 

SV

 for you to program start voltage for the loco. If 

you do not want to program start voltage, just press 

Enter

. If you do want to 

program start voltage, input a value and then press Enter. The value range 

to select differs with different types and brands of decoders. Check your 

decoder instructions for the range available. 
Next, it will prompt with 

ACC

 for you to program acceleration rate for the 

loco. If you do not want to program acceleration rate, just press 

Enter

. If you 

do want to program acceleration rate, input a value and then press 

Enter

Next, it will prompt with 

dEC

 for you to program deceleration rate for the 

loco. If you do not want to program deceleration rate, just press 

Enter

. If you 

do want to program deceleration rate, input a value and then press 

Enter

Next, it will prompt with 

CV#

 for you to program a configuration variable for 

the loco. If you do not want to program a CV, just press 

Enter

. If you want to 

program a CV, input the CV 

number

 you want to program and then press 

Enter

. The system will prompt 

CV

. Enter the CV 

value

 and then press 

Enter

. Your decoder instructions should include a list of all CVs and their 

value ranges. 
Next, it will prompt with 

CV#

 again for you to program another CV for the 

loco. If you do not want to program another CV, just press 

Enter

 

OPERATION (DUAL MODE) 

Once you assign a loco address to your loco, you can select it and operate 

it. To select a loco, press 

Loco

 and input the loco number and press 

Enter

Use the throttle knob to control the speed and the direction key to change 

direction. Top speed is 126. The knob will continue to turn past 126 but the 

maximum speed is 126. You can also use the 

+

 and 

 keys to increase or 

decrease the speed incrementally by 1. It is a good method of speed control 

when doing yard work or coupling. 

 

2

 

RECALL FEATURE (DUAL MODE) 

Once you select a loco, its information will be stored in the recall stack. 

You can press recall to scroll through the locos you have been operating. 

Select the one you want and begin to operate it. If you wish to remove a 

loco from the stack, simply hold 

Del

 for two seconds. 

In order to save all 

your settings, be certain to press the 

Loco

 button twice before shutting 

down for the day. 

Make sure to set all loco addresses to zero speed before turning off 

the power to your Tech 6; otherwise when re-powering up the 

system, your decoder equipped loco will start at their last used 

speed. 

 
EMERGENCY STOP (DUAL MODE) 

Press 

Stop

 to stop the current loco. Press and hold 

Stop

 for two seconds 

to stop all locos. To restore layout power, press and hold 

Stop

 again for 

two seconds. 
 

TO SAVE YOUR SETTINGS 

BEFORE unplugging your walkaround, always press the 

Loco

 button 

twice to save your settings. 

Always do this before shutting down for the 

day. 

 

NOTE

: Once the walkaround is plugged in, it will disable the base unit. To 

regain control of the base unit when not using the walkaround, you must 

press 

Enter

 or the direction key on the base unit. 

 

 __________________________________________  

 

WALKAROUND MOBILITY 

If you wish to move around your entire layout using this walkaround, you can 

purchase item 0001501 Extension Plate (the cable is included). You can mount 

extension plates around your layout, and you can unplug the walkaround and 

move from jack to jack while your trains are underway. 

 

 
 
 
 
 
 
 
 

 

 

 

 

 

SERVICE 

 

Your Tech 6 Walkaround Controller has been thoroughly tested before leaving 

our facility. If for some reason you are having problems with your Tech 6 

Walkaround, please contact MRC Customer Support using the contact 

information 

prior to

 sending the unit for service. 

 

The unit carries a six (6) month warranty against factory defects.

 This 

warranty 

does not

 include abuse, misuse, neglect, improper installation, 

unintended use, or any modifications made to the product. If it should become 

necessary to return the product for warranty repair/replacement, be sure to 

contact MRC technical support 

beforehand

 to ensure you receive the correct 

fees for service. This also gives us the opportunity to troubleshoot issues 

which may be solved with technical phone support. 

The six-month warranty does not include return shipping for customers 

outside of the continental United States (including Hawaii, Alaska, Canada, 

and Mexico). Customers outside of the continental United States must contact 

us for return shipping rates. 

Questions regarding the six-month warranty policy or troubleshooting issues 

can be directed to 

MRC Customer Support

 by calling 

1-732-225-6360

 from 

Monday to Friday between 8:00am and 5:00pm EST or by emailing 

[email protected]

In order to receive warranty service, we require a copy of the original sales 

receipt to validate the warranty period. Include a note briefly describing the 

issues along with your name, address, phone number, and email address. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Model Rectifier Corporation 

360 Main St. STE # 2 

Matawan, NJ 07747 USA 

Telephone 1-732-225-6360 

www.modelrectifier.com 

 
© 2019 Model Rectifier Corporation   

Printed in USA 

 

 

 

SET UP AND INTRODUCTION 

Use either end of the extension cable and plug one end into the 

walkaround and plug the other end into the Tech 6 Sound Controller. 

Turn on the Tech 6 Sound Controller and the LCD will light up on the 

walkaround. Only one walkaround can be used with the Tech 6 Sound 

Controller. Plugging in another walkaround may cause damage to the 

system. 
Just like the Tech 6 Sound Controller you can either run standard locos 

or decoder equipped locos but not both at the same time. In “Dual 

Mode”, the Tech 6 Walkaround Controller will enable you to operate up 

to six decoder equipped locos using addresses 1, 2, 3, 4, 5 and 6. 

  __________________________________________  

 

STANDARD NON-DECODER EQUPPED LOCO OPERATON 

WITH THE WALKAROUND 

You can operate one standard non-decoder equipped loco on your 

layout with the walkaround. 
The start voltage, acceleration, deceleration and top voltage 

cannot

 

be programmed from the walkaround when using an analog 

standard locomotive. Adjust these parameters using the base unit 

prior to

 plugging the walkaround into the base unit. 

Before placing a non-decoder equipped loco on the tracks, make 

sure your Tech 6 Sound Controller is set to 

STD

 (standard) mode 

and the yellow LED is lit on the base unit. 
The walkaround will display ‘Loco.’ 
Use the throttle knob to control the speed and the direction key to 

change direction. Top speed is 126. The knob will continue to turn 

past 126 but the maximum speed is 126. You can also use the 

+

 

and 

 keys to increase or decrease the speed incrementally by 1. It 

is a good method of speed control when doing yard work or 

coupling. 
Press 

Stop

 to stop the loco. Pressing and holding 

Stop

 for two 

seconds will turn off power to the layout. The walkarournd display 

will flash 

oFF

. To restore layout power, press and hold 

Stop

 again 

for two seconds. 

NOTE:

 Once the walkaround is plugged in, it will disable the base 

unit. To regain control of the base unit when not using the 

walkaround, you must press 

Enter

 or the direction key on the base 

unit. 

 

TECH 6 WALKAROUND CONTROLLER

 

Item: 0001203

 

Reviews: