Operation Manual 

SI-500 

Mix Smart 

 

 

PLEASE READ THIS MANUAL CAREFULLY BEFORE 

OPERATION 

 

3, Hagavish st. Israel 58817    Tel: 972 3 5595252, Fax: 972 3 5594529      [email protected] 

 

MRC.VER.01-12.12 

 

Summary of Contents for SI-500 Mix Smart

Page 1: ...Operation Manual SI 500 Mix Smart PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC VER 01 12 12 ...

Page 2: ...rder to use the instrument properly please read this manual carefully before using the Instrument Opening Check Please check the Instrument and Appendix with the packing list when you first open the instrument packing case If you find there is something wrong with the Instrument and the Appendix do contact the vendor or the producer ...

Page 3: ...se in laboratory environments The device must be used by skilled personnel with the appropriate training The operator should not open or repair the Instrument by himself which will result in losing the qualification of repair guarantee or occur accident If there is some wrong with the Instrument the company will During the normal operation the temperature of metal block will be very high There wil...

Page 4: ...nd contact the vendor There is some liquid flowing into the Instrument Drenched or fire burned Abnormal operation such as abnormal sound or smell Instrument dropping or outer shell damaged The function has obviously changed Before power on guarantee the voltage used should be accordant to the voltage needed and the rated load of electrical outlet should not lower than the demand If the electric li...

Page 5: ... 2 Chapter 3 Preparations 3 1 Structure Description 3 2 Keyboard and Display pane 4 3 Optional tube holder for the Mix Smart 5 4 Insert plates and tubes 5 5 Power connection 6 Chapter 4 Operation Guide 7 1 Speed and time setting 7 2 Touch Vortex mode with 3500rpm 8 3 Key combination 8 Chapter 5 Failure analysis and handling 9 ANNEX 1 Wiring Diagram for SI 500 10 ...

Page 6: ...t tubes or plates The Mix Smart supports from 0 2 ml PCR tubes to 2 0 ml micro test tubes as well as PCR MTP and DWP plates up to 384 wells Features 2DMix Control Optimized mixing Anti spill technology 3 in 1 format allows great flexibility Preprogrammed soft keys Reliable universal holder LED display it is easy to setup and use Extremely quiet operation 50 dB A Integrated vortex function ...

Page 7: ...lders 0 5 ml 1 5 2 0 ml and PCR 96 with max 2000rpm 2 It only mix at a load between 80 300g with a maximum mixing frequency of 2000rpm 3 When the load is too much and even the speed is more than 2000rpm it reduces the mixing frequency automatically to 1400rpm In the display the message Too Fast appears Mixing frequency 300 3 000rpm in 10rpm increments Touch vortexing frequency 3 500rpm Adjustable ...

Page 8: ...late holder To hold skirted PCR plates MTP and DWP as well as tube holders b Soft keys For selecting preset mixing parameters c Vortexing mat For direct vortexing of various tubes d Operating controls Keys for operating the speed and time e LED display Display mixing frequency and mixing time f Mains power switch Switch for switching the device on and off Switch position O the device is switched o...

Page 9: ...TP and DWP 384 well 10 60 2600 15 PCR Plate 384 well 10 50 1000 30 MTP 96 well 5 60 1650 30 PCR tubes 0 2ml and micro test tubes 0 5ml 5 50 LED Display Window Start stop mixing run Decreasing key for speed and time it can setup speed and time Increasing key for speed and time it can setup speed and time Start Stop 1 5 2 0 96 PCR 384 PCR96 0 5 384 ...

Page 10: ...nd 2 0ml b PCR 96 tube holder For one PCR plate 96 well semi skirted or unskirted or a max of 96 micro test tubes 0 2ml c 0 5ml tube holder For max 24 micro test tubes 0 5ml 4 Insert plates and tubes 4 1 Insert plate in the plate holder a Place the plate up against the back of the plate holder firstly b Then press the plate into the plate holder In doing so ensure that it is properly engaged a b c...

Page 11: ...es See fig a b Engage the tube holder by pressing gently on the front See fig b a b 5 Power connection Place the Mix Smart on a suitable work surface so that the air slots on the underside of the device are not blocked Connect the device to the mains power supply via the mains power socket using the mains cable supplied The external power supply unit power adapter AC100 240V ensures the external s...

Page 12: ...l increase or decrease and also increase or decrease in hundred digits and thousand digits For instance press the key and hold on for 2s the digits will be moved from tens to hundreds increasing the alteration range If you press the key for 2s again the digits will be moved from hundreds to thousands quickly d Press key or below time units will increase or decrease and also increase or decrease in...

Page 13: ...ad from the vortexing mat to end the Touch Vortex mode 3 Key combination a Time unit switch mode Press key and key below time simultaneously to switch time unit from h m to m s flicks three times then save automatically The way to switch from m s to h m is the same to above b Key lock function Press keys below speed and time simultaneously to activate the key lock funtion The key lock prevent from...

Page 14: ...xing frequency Reduce the mixing frequency or the weight of the mixing load Mixing load not properly positioned in the plate holder Check that the mixing load is fixed in position 2 TOO FAST Continuous vortexing at frequencies 2000rpm Reduce the continuous vortexing frequency to 2000rpm 3 The actual speed is different from the displayed speed Broken sensor or loose contact of the module Contact th...

Page 15: ...ix Smart Operational Manual Chapter 5 Failure analysis and handling Annex 1 Wiring Diagram for SI 500 Mix Smart Adapter 48W AC100 240V Motor Switch Key and Display Main Board J5 J6 LCD PORT J2 J4 J1 U J7 V J8 W ...