background image

Meter

PC

(9W 'D" Connector)

Center Pin..........................Pin 4

(3.5 mm jack plug)
 Ground/shield.......................Pin 2

 2.2 K
resistor

Pin 5

The 16 digits data stream will be displayed in the
following  format :

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0

Each digit indicates the following status :
D0

End Word

D1 & D8

Display reading, D1 = LSD, D8 = MSD
For example : 

If the display reading is 1234, then D8 to
D1 is : 00001234

D9

Decimal Point(DP), position from right to the
left
0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP

D10

Polarity
0 = Positive 1 = Negative

D11 & D12 Annunciator for Display

ACV = 50 

 W = 47

 A = 52

PF = 54

D13

When send the upper display data = 1
When send the lower display data = 2

D14

4

D15

Start Word

9

Summary of Contents for DW-6163

Page 1: ...TER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t i n g t e c h n i q u e s a r e developed Please read t h e f o l l o w i n g instructions carefully and always keep this manual within easy reach OPERATION MANUAL 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 5 19 ...

Page 2: ...voltage current to the input terminal Remove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Installation Categories III 600V Pollution Degree 2 Altitude up to 2000 meters Indoor use Relative humidity 80 max ...

Page 3: ...URCE terminal 4 3 8 RS 232 output terminal 4 3 9 DC 9V Power Adapter input socket 4 3 10 Battery Cover Compartment 4 3 11 Stand 4 4 MEASUREING PROCEDURES 5 4 1 Power ON OFF 5 4 2 ACV measurement procedure 5 4 3 ACA measurement procedure 5 4 4 Watt measurement procedure 6 4 5 Data Hold 6 4 6 Data Record Max Min reading 6 4 7 Backlight ON OFF 7 4 8 Auto power management 7 5 MAINTENANCE 8 6 RS232 PC ...

Page 4: ...e Full function Auto range Memory Record Max Min Data Hold RS232 USB Computer interface Built in low battery indicator Built in backlight easy to readout Power DC 9V 006P or AC to DC 9V adapter in 2 SPECIFICATIONS 2 1 General Specifications Circuit Custom one chip of microprocessor LSI circuit Display Large LCD display max reading 9999 Digit size 21 8 x 8 5 mm Dual value display with backlight Mea...

Page 5: ...tion Weight 398 g 0 88 LB Dimension 190 x 88 x 40 mm 7 5 x 3 5 x 1 6 inch Accessories Instruction manual 1 PC Included Test lead Red Black 1 Pair Optional AC TO DC 9V adapter Accessories USB cable USB 01 RS232 cable UPCB 02 Data Acquisition software SW U801 WIN Excel Data Acquisition software SW E802 2 2 Electrical Specifications 23 5 WATT TRUE POWER Range Resolution Accuracy 6000 W 1 W 1 5 W Auto...

Page 6: ... Hz Max input value AC voltage 600V AC current 10 A Accuracy 23 5 PF Power factor Range Resolution Accuracy 1 00 0 01 1 2d ACV ACA accuracy is test under input signal is sine wave 50 60 Hz ACV ACA frequency response is from 40 to 400 Hz Max input value AC voltage 600V AC current 10 A Accuracy 23 5 Above specification tests under the environment RF Field Strength less than 3 V M frequency less than...

Page 7: ...ay 3 2 POWER Backlight button 3 3 FUNCTION button 3 4 HOLD button 3 5 RECORD button MAX MIN 3 6 LOAD terminal 3 7 POWER SOURCE terminal 3 8 RS 232 output terminal 3 9 DC 9V Power Adapter input socket 3 10 Battery Cover Compartment 3 11 STAND 4 ...

Page 8: ... use the test lead measurement unknown AC voltage 5 Read the up display The value indicated corresponds to the position selected If the Display shows it indicates an Out of range measurement 4 3 ACA measurement procedure 1 Press the POWER button 3 2 Fig 1 more than 1 5 sec to Turn ON the meter 2 Push the FUNCTION button 3 3 Fig 1 once then change function for measuring ACA 3 Connect red test lead ...

Page 9: ...ent power switch Let it work then you can read out the POWER CONSUMPTION from the bottom of the LCD display value 9 At the same time Push the FUNCTION button 3 3 Fig 1 once then change function for measuring WATT PF 10 Now you can take the Active Power value and Power Factor value from the LCD display 4 5 Data Hold During the measurement press the Hold Button 3 4 Fig 1 once will hold the measured ...

Page 10: ...te the memory function continuously c To exit the memory record function just press the REC button for 2 seconds at least The display will revert to the current reading 4 7 Backlight ON OFF 1 When use the instrument in a dark place or under the SUN You can turn ON the Backlight for easy readout 2 If the instrument is working Press the POWER button 3 2 Fig 1 once can turn ON the Backlight 3 Press t...

Page 11: ...ed periodically 4 Do not leave the instrument exposed to direct heat from the sun for long periods 5 Before removing the battery compartment cover ensure that the instrument is disconnect from any circuit and the power switch is on the OFF position 6 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 8 Fig 1 The data output is a 16 digit stream which can...

Page 12: ...ch digit indicates the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D10 Polarity 0 Positive 1 Negative D11 D12 Annunciator for Display ACV 50 W 47 A 52 PF 54 D13 When send the upper display data 1 When send the lower display data ...

Page 13: ... on LCD display show it is necessary to replace the battery However in spec measurement may still be made for several hours after LOW BATTERY INDICATOR appears before the instrument become inaccurate 2 Open the screw of Battery Cover by screwdriver then move the battery 3 Replace with 9V battery and reinstate the cover 8 THE ADDRES OF AFTER CENTER 10 ...

Reviews: