background image

1.2.4

 

Warning Signs 

Sign 

Description 

Danger 

It shows that the situation is  very dangerous and  will lead  to death or 

serious injury. 

Warning 

It shows that the situation is  very dangerous and  will lead  to death or 

serious injury 

Note 

It shows that the situation is very dangerous and will lead to injury. 

Prohibit 

Get wet in the rain or splashing water. 

Note 

Do not close to the rotary parts

 

Note 

Please wear protective equipment, otherwise may cause personal injury 

Reminder

 

Reminder 

May cause equipment damage.

 

Especially pay attention to each warning sign. 

Summary of Contents for COT Series

Page 1: ...Operation Manual COLD TRAPS COT SERIES PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 9 20...

Page 2: ...onfiguration 8 1 4 4 COT 5000L Configuration 8 1 5 CONTROL PANEL INSTRUCTION 9 1 5 1 COT 2000H COT 5000H Control Panel Instruction 9 1 5 2 COT 2000L COT 5000L Control Panel Instruction 9 2 UNPACKINGAN...

Page 3: ...2 6 2 MAINTENANCE OF COOLING SYSTEM 15 6 3 MAINTENANCE REQUIREMENT 15 6 4 COMMON FAILURES AND TROUBLESHOOTING 16...

Page 4: ...rasp of the detailed requirements in this manual Otherwise it must be used under the guidance of the person who has the related technology skills 1 2 2 Proper Use COT series cold traps are required to...

Page 5: ...dangerous and will lead to death or serious injury Note It shows that the situation is very dangerous and will lead to injury Prohibit Get wet in the rain or splashing water Note Do not close to the r...

Page 6: ...ll to avoid electric shock If found refrigerant leak please take ventilation measures to reduce refrigerant content in the air as soon as possible The recycling material should has no corrosive on SUS...

Page 7: ...ife will be affected Do not contact refrigerant with food medicines tobacco etc to avoid personal injury 1 2 7 Safety Measures Please wear personal protective equipment such as protective glasses prot...

Page 8: ...US304 knob 2 Sealing flange 3 Control panel 4 Wheel 5 Breaker 6 Power cord 7 Air outlet 8 Liquid outlet 9 Air inlet 1 4 2 COT 5000H Configuration Figure 1 4 2 1 SUS304 knob 2 Sealing flange 3 Breaker...

Page 9: ...aling flange 3 Control panel 4 Wheel 5 Breaker 6 Power cord 8 Air outlet 9 Liquid outlet 7 Air inlet 1 4 4 COT 5000L Configuration Figure 1 4 4 1 SUS304 knob 2 Sealing flange 3 Control panel 4 Air out...

Page 10: ...re display window 2 Up 3 Down 4 Set 5 Power Switch 6Cooling Switch 7Circulaion Switch disabled 1 5 2 COT 2000L COT 5000L Control Panel Instruction Figure 1 5 2 Control Panel 1 Measured value and Menu...

Page 11: ...ace the device steady place more than 12h and then start debugging 3 Keep well ventilated the environment temperature should less than 35 Note Do not cover the air inlet outlet 4 Connect air outlet wi...

Page 12: ...n working temperature range Safety protection Time delay over current over heat Dehumidification capacity Max 1kg water Max 1kg water Max 4kg water Max 4kg water Cooling capacity W 10 640 920 20 400 5...

Page 13: ...electric shock or equipment damage if you don t connect the power supply as described in 4 1 4 2 Power on 4 2 1Close Breaker Set the breaker which located on the right side of the instrument to then...

Page 14: ...tem at 40 Press after set all the parameters the compressor will start working after delay time the cooling system will working continuously 4 3 2 Start Refrigeration System at 80 Press after set all...

Page 15: ...set before leaving the factory users do not change it 6 Maintenance and Management Ensure to make the equipment running normally to increase its service life users should do daily maintenance and mana...

Page 16: ...up the cooling system condenser regularly Please follow the steps below 1 Turn off the power supply 2 Take down the screws then pull the side panel down 3 Clean up the dust on the condenser fin Sugge...

Page 17: ...ensor breakdown Replace sensor 4 Temperature lose control Voltage fluctuation range large Restart the device after voltage stabilization Temperature controller connection failure Stop using it and con...

Page 18: ...airflow or airflow abnormal The fan has not started Stop using it and contact us or professional maintenance personnel The fan has started The fan was stuck Blade deformation Our company reserves the...