background image

AIS-4

Compressed Air Sampler 

Instruction 

ISO9001-2008 Certified Enterprise 

PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Hagavish st. Israel 58817  Tel: 972 3 5595252, Fax: 972 3 5594529   

[email protected]

MRC.

3

.

22

Summary of Contents for AIS-4

Page 1: ...Compressed Air Sampler Instruction ISO9001 2008 Certified Enterprise PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC...

Page 2: ...oper use of this equipment please keep it for future reference Directory I Equipment Introduction 1 II Application 1 III Working Environment 1 IV Main Features 1 V Technical Parameters 2 VI Product Li...

Page 3: ...etsec 23 1 to 23 5 m sec at 200 L min The surface of the medium is equivalent an 1hAnderson Principle 5 Grade 6 at 200L min ensuring that all particles larger t ish wasdmicron 0 65 micron at 200L min...

Page 4: ...pling design the sampling head with up to 300 microporous so that micro organisms evenly distributed in the surface of the medium to reduce the dust bacteria overlap effectively reduce the microbial c...

Page 5: ...set Lithium battery charger DC 8 4V 1000mA 1set Manual certificate warranty card 1 set USB data cable 1 Piece VII Structural Features 1 The composition of the sampler includes gas dispersing head sam...

Page 6: ...4 quick connector gas dispersing head sampling head air pressure regulating valve control panel gas flow meter outlet air inlet switch charging interface purifier internal...

Page 7: ...ired for microbial culture according to the requirements of the experiment and prepare the corresponding plate Before starting sampling make sure that the storage temperature of the sampling petri dis...

Page 8: ...state please open the external compressed gas tank valve compressed gas will be through the air inlet pressure control valve gas flow See section 4 of this chapter After adjustment press Start to proc...

Page 9: ...or 30 minutes or wiped with 75 alcohol at the high pressure steam sterilizer The gas dispersing head the Petri dish and the appearance of the instrument are also used 75 alcohol for wipe sterilization...

Page 10: ...lly lock the baffle screws 5 the system function menu description Working mode selection In the main interface press key to select the working mode as program control manual control self purification...

Page 11: ...all sampling records Please choose carefully View the record In the main interface press the Select button to enter the record query interface you can view all the sampling record data including sampl...

Page 12: ...thod not mentioned above consult the manufacturer or agent to determine if the method used will damage the instrument 6 The display shows that when the battery power is low the battery is displayed as...

Reviews:

Related manuals for AIS-4