GENERAL INSTALLATION

(cont.)

Clearance to heat sources

• Do not install the AromaSteam system directly below or above the Mr. Steam steam

generator where it is subject to heat.

• Minimum distance between the AromaSteam system and a heat source (e.g. steam

generator, heating system) is 1.5 ft. If this minimum distance of 1.5 ft cannot be maintained,
install a radiation plate or heat insulation between the heat source and AromaSteam system.

• Ambient temperature at and around the AromaSteam system should not exceed 90˚ F.

Installing the 90 degree T and Atomizing Nozzle

1. For optimal results locate a brass 90 degree

T

(not provided) and atomizing nozzle

in the steam supply line within 10 feet of the steam head. If using copper tubing for
steam lines, install a female 1/2 NPT thread to sweat fitting in the downward facing

T

.

2.

T

must face downward as shown (in figure 2).

3. Screw the atomizing nozzle into 90°

T

fitting using teflon tape on the threads.

IMPORTANT NOTE: Follow the installation instructions for the steam
pipeline in the Mr.Steam Steam Bath Installation and Operation Manual.
Visit www.mrsteam.com to download this document.

Steam Line

90˚ T

Figure 2

1/2 NPT

4

Installation of Pressure Hose to AromaSteam System

1. Unscrew the pressure end nut from the pump head and remove the

shipping hose and the pressure end nut.

2. Insert the pressure hose through the hole of the pressure end nut and

firmly push the pressure hose onto the pressure valve.

3. Screw the pressure end nut onto the pressure valve and tighten the nut

by HAND only.

Installation of Suction Hose in Scent Container

1. Locate the “container cap”.

2. Unscrew the cap from the Mr.Steam scent container and discard.

3. Insert the suction hose with the open end from below through the

hole in the container cap (see Fig. 3).

4. Insert the filter into the scent container so that the filter rests on the

bottom.

5. Screw the cap onto the scent container.

Open End

Container Cap

Suction Hose

Filter

C

on

ta

in

er

H

ei

gh

t

8

in

ch

es

Figure 3

Summary of Contents for aromasteam

Page 1: ...mr steam Feel Good Inc AromaSteam Installation Operation Maintenance Manual ...

Page 2: ...operation with this system The use of any oils other than Mr Steam oils may introduce excessive concentration of oil into the steam room resulting in a health hazard Vapors may cause drowsiness and dizziness Keep out of the reach of children In case of contact with eyes rinse immediately with plenty of water and seek medical advice If swallowed rinse mouth with water only if the person is consciou...

Page 3: ...ect to moisture condensation or similar high humidity envi ronments 4 Do not install AromaSteam Systems outdoors 5 Do not install AromaSteam Systems in a location where water could freeze 6 Do not install AromaSteam Systems near flammable or corrosive materials and chemicals Installation in areas having high concentrations of chlorine such as pool equipment room should be avoided CAUTION 6 ft Pres...

Page 4: ...ng T 2 T must face downward as shown in figure 2 3 Screw the atomizing nozzle into 90 T fitting using teflon tape on the threads IMPORTANT NOTE Follow the installation instructions for the steam pipeline in the Mr Steam Steam Bath Installation and Operation Manual Visit www mrsteam com to download this document Steam Line 90 T Figure 2 1 2 NPT 4 Installation of Pressure Hose to AromaSteam System 1...

Page 5: ...on end nut 4 Firmly push the hose onto the cone of the suction valve at the pump head 5 Screw the suction end nut to the suction valve IMPORTANT NOTE HAND TIGHTEN ONLY Max ht 6 ft iSteam Steam Line Typical Mr Steam Steam Generator Cable to Steam Generator request cable Atomzer Nozzle Pressure Hose 90 T Suction Hose Scent Container Pump Line Cord 120V grounded receptacle required AromaSteam System ...

Page 6: ...t tabs labeled AROMA on the PC board in the location show 4 Connect the request cable to the terminals The terminals are not polarized 6 Figure 5 Pressure Valve Injector Hose Push Button AromaSteam Metering Pump START UP Initial Priming of the Pump 1 Insure Mr Steam scent container is full 2 Insert the short injector hose onto the tip of the injector see Fig 5 3 Unscrew the pressure end nut from t...

Page 7: ...ma oils will automatically be pumped into the steam line at preset intervals Adjusting the Amount of Oil Deliver The AromaSteam system has been factory set to deliver a suitable amount of aromatic oil into a typical sized steam room Please contact the MrSteam Technical Service Department before changing this setting Increasing the settings may introduce excessive concentra tion of oil into the ste...

Page 8: ...il into steam room 1 Check if voltage is available 2 Check liquid level in scent container Replenish liquid if necessary 3 Check for air bubbles in the suction hose or the pump head To eliminate air bubbles see Priming Pump 4 Check valves for contamination Clean valves if necessary 5 Check filter in container for contamination Rinse filter under clean water 6 Check the pressure hose for kinking or...