mr
.
steam
®
AromaSteam
Operation and Installation Instructions
______________________________________________________________________________________________
GENERAL INSTALLATION
(cont.)
Clearance to heat sources
• Do not install the AromaSteam system directly below or above the Mr. Steam steam
generator where it is subject to heat.
• Minimum distance between the AromaSteam system and a heat source (e.g. steam
generator, heating system) is 1.5 ft. If this minimum distance of 1.5 ft cannot be maintained,
install a radiation plate or heat insulation between the heat source and AromaSteam system.
• Ambient temperature at and around the AromaSteam system should not exceed 90˚ F.
Installing the 90 degree T and Atomizing Nozzle
1. For optimal results locate a brass 90 degree
T
(not provided) and atomizing nozzle
in the steam supply line within 10 feet of the steam head. If using copper tubing for
steam lines, install a female 1/2 NPT thread to sweat fitting in the downward facing
T
.
2.
T
must face downward as shown (in figure 2).
3. Screw the atomizing nozzle into 90°
T
fitting using teflon tape on the threads.
IMPORTANT NOTE: Follow the installation instructions for the steam
pipeline in the Mr.Steam Steam Bath Installation and Operation Manual.
Visit www.mrsteam.com to download this document.
Steam Line
90˚ T
Figure 2
1/2 NPT
4
Installation of Pressure Hose to AromaSteam System
1. Unscrew the pressure end nut from the pump head and remove the
shipping hose and the pressure end nut.
2. Insert the pressure hose through the hole of the pressure end nut and
firmly push the pressure hose onto the pressure valve.
3. Screw the pressure end nut onto the pressure valve and tighten the nut
by HAND only.
Installation of Suction Hose in Scent Container
1. Locate the “container cap”.
2. Unscrew the cap from the Mr.Steam scent container and discard.
3. Insert the suction hose with the open end from below through the
hole in the container cap (see Fig. 3).
4. Insert the filter into the scent container so that the filter rests on the
bottom.
5. Screw the cap onto the scent container.
Open End
Container Cap
Suction Hose
Filter
C
on
ta
in
er
H
ei
gh
t
8
in
ch
es
Figure 3