Battery replacement

The batteries in AirTempo will need periodic replacement. Both batteries 

should be replaced at the same time with new CR2450 coin cell batteries.

 

 CHOKE HAZARD. The batteries and battery doors are small 

pieces, keep out of reach of children.

 

 KEEP BATTERIES OUT OF REACH OF CHILDREN.  

Swallowing may lead to serious injury or death in as little as 2 hours due to 

chemical burns and potential perforation of the esophagus. Immediately 

see a doctor.

Remove the AirTempo from the wall by sliding it up and off the bayonet holder. 

The AirTempo comes off the flush mount holder by grasping the bezel and pulling 

the assembly straight out of the flush mount box.

Use a soft cloth to dry off the control. 

With two fingers turn the battery doors in the direction noted. The left battery  

cover is opened by turning it clockwise, the right cover is opened by turning it 

counterclockwise.

Discard both batteries and replace with new batteries, the positive side of the  

battery goes towards the “+” symbol on the battery door.

WarNiNG

!

WarNiNG

!

CaUtiON

!

System Status Codes

The AirTempo may display a status code if the steam system is not function-
ing correctly.

err C

 indicates the AirTempo control has lost communication with the steam 

generator. Ensure all connections are secure between the steam generator 

and the transceiver

err p

 indicates an error while pairing, reset the control and redo pairing.

A complete list of steam generator status codes can be found in the MrSteam  

Residential Steambath Installation Operation and Maintenance Manual.

pairing

AirTempos are factory paired, however if more than one steam system is  

installed in close proximity the AirTempo controls must be paired to their 

transceivers to prevent interference. 
To pair AirTempo use a blunt object to press the button inside the transceiver 

adjacent to the LED.  Hold the button for 5 seconds, when the transceiver  

is in pairing mode the LED will turn blink blue for 2 minutes.
While the transceiver LED is blinking, press and hold the          button on  

AirTempo for 5 seconds until the display reads PAIR.

Replace the battery door and lock in place.

 

To prevent water from getting in the control in-

gress, ensure the battery doors are in the locked position before 
reinstalling control.

Care tips for airtempo Controls and Steamheads

1. Use only mild soap and water on a soft cloth to clean  

the control and steamhead.

2. Do not use abrasive cleansers

3. If the decorative cover is damaged call MrSteam  

technical service for replacement parts.

Warranty

To register your steam generator unit online and to review  
the MrSteam Limited Lifetime Warranty please go to: 

blog.mrsteam.com/wr 

Summary of Contents for AirTempo

Page 1: ...Operating Maintenance Instructions ________________________________________________________________________________________________ 1 AirTempo Wireless Touch Control with Steamhead Installation Operat...

Page 2: ...ing and caution symbols This blocked information is important for the safe and ef ficient installation and operation of the steambath system These are types of potential hazards that may occur during...

Page 3: ...quate heating of the steam room If an AirTempo iSteam iTempo or iTempoPlus control is installed outside the steam CAUTION room a Remote Temperature Probe PN MSTS must be installed inside the steam roo...

Page 4: ...he surface mount bayonet supports the weight of the AitTempo control if requires use the screw and anchor provided to secure the bayonet to the wall When installing AirTempo on glass the peel and stic...

Page 5: ...ar the steamhead or near direct steam emis sions may result in poor steam room temperature control d The probe has an integral 30 cable Insure that the probe and or steam generator are located accordi...

Page 6: ...irTempo features programmable temperature control programmable time duration AromaSteam ON OFF ChromaSteam control and two personal settings The LCD will be OFF until a button is pressed The LCD remai...

Page 7: ...steambath will operate at the stored settings Diagram 3 Diagram 4 TEMP Time Temperature adjustment User Preset AromaSteam The AromaSteam is an optional accessory that automatically injects aromatic oi...

Page 8: ...splay a status code if the steam system is not function ing correctly Err C indicates the AirTempo control has lost communication with the steam generator Ensure all connections are secure between the...

Page 9: ...pourraient annuler l autorit de l utilisateur utiliser cet quipement Parts List Item Description Used on 104208BK Electronic Assembly Black All 104208WH Electronic Assembly White All 104209 Retention...

Page 10: ...18 19...

Page 11: ...n call Sales Support at 1 800 76 STEAM East Coast 1 800 72 STEAM West Coast mr steam Sussman Automatic Corporation hello mrsteam com www mrsteam com 43 20 34th Street Long island City NY 11101 9410 S...

Reviews: