background image

9

WARNING:  READ  CAREFULLY  THIS  INSTRUCTIONS  BEFORE  INSTALLING 

AND COMMISSIONING THE PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE.

PRODUCT INSTALLATION

The product at issue must be installed, commissioned 

and  maintained  only  by  licensed  and  authorised 

people,  respecting  the  laws  concerning  the  electrical 

installations.  Not  conforming  installations,  wrong 

adjustments  or 

product  alterations  may  cause  fire, 

electric  shock,  or  personal  injuries.  The  manufacturer 

is  not  responsible  for 

any  damage  due  to  wrong 

installation or improper use. 

Attention: at the power-

on the device resumes the status it had before the 

turning-off.
ELECTRICAL CONNECTIONS

All  the  connections  must  be  rated  for  a  single-phase 

230Vac  power  supply,  with  the  relative  Earth 

connection. For the disconnection from the power line, 

use  an  all-pole  switch  with  contacts  having  a 

dimension  of  at  least  3

.

5mm.  Arrange 

all  the 

necessary  safety  devices 

and  use  only  materials 

complying with the standard of electrical installations. 

The cable must have a section properly rated according 

to  the  load  connected. 

Attention:

 

If  any  cable  is 

damaged,  it  must  be  immediately  replaced  by  a 

qualified  person  in  order  to  avoid  any  hazard.

 

manufacturer  reserves  the  right  for  changing 

technical data and features without prior notice.

SAFETY INFORMATION

Do not operate in the high voltage area of the electronic 

board,  when  it  is  supplied.  Use  the  product  only  in 

combination  with  devices  which  can  guarantee  a  safe 

extended time functioning. The radio signal reception of 

the  device  could  be  disturbed  by  the  presence  of 

electrical  disturbances  being  transmitted  by  other 

appliances  working  on  the  same  frequency  or    if  the 

product is somehow shielded by metal parts.

PRODUCT DISPOSAL

At  the  end  of  this  product’s  useful  life,  it  must  not  be 

disposed of as domestic waste, but must be taken to a 

collection  centre  for  waste  electrical  and  electronic 

equipment. It is the user’s responsibility to dispose of this 

appliance through the appropriate channels at the end of 

its  useful  life.  Failure  to  do  so  may  incur  the  penalties 

established by laws governing waste disposal. 

In  the  view  of  a  constant  development  of  their 

products,  the  manufacturer  reserves  the  right  for 

changing technical data and features without prior 

notice.

Summary of Contents for TVDMM868G10S

Page 1: ...t code 165 mm 47 mm Fixing holes 35 mm Mounting L 1 2 3 4 5 6 10 9 8 7 N L N L N RELAY BALLAST TRANSFORMER 1 L Led 1 P1 P2 P3 Led 2 Led 3 Led 4 IN 1 2 3 4 5 6 1 10V 0 10V 10 9 8 7 OUT N L N 0 1 10V OU...

Page 2: ...y OFF OFF Relay OFF To test the wiring press P1 P1 0 5 s ON OFF 0 5 s DIMMER L 1 2 3 4 5 6 10 9 8 7 N L N L N L N L N RELAY BALLAST TRANSFORMER 1 BALLAST TRANSFORMER 2 L Led 1 P1 P2 P3 Led 2 Led 3 Led...

Page 3: ...nsmitter with integrated light sensor See the product s instructions for details Single command channel with function ON OFF or ON OFF DIM Wireless command devices Activation deactivation of the memor...

Page 4: ...3 P2 7 channels x1 Press the button of the transmitter relative to the code to memorize 1 button x2 1 button with function ON x3 1 button with function OFF x4 Green Mouse x5 keep it pressed continuou...

Page 5: ...d in the remote memorization 3 1 the added transmitter will have the same modified values Modification of the preset light values of a 7 42 channel transmitter 2 3 CH1 CH2 CH3 CH4 CH5 CH6 CH7 2 1 CH1...

Page 6: ...smitter The added radio code will have the same functions of the code used for the memorization This procedure is compatible with any type of transmitter P3 button is located inside the transmitter Pr...

Page 7: ...10 11 12 13 14 1 2 3 4 12 24Vdc OU T 12 24Vdc IN 5 6 7 8 9 10 11 12 13 14 1 2 3 4 12 24Vdc OU T 12 24Vdc IN 9 10 11 12 13 14 1 2 3 4 12 24Vdc OU T 12 24Vdc IN 9 10 11 12 13 14 1 2 3 4 12 24Vdc OU T 12...

Page 8: ...mmer will have the load OFF address Press the button relative to the value to modify CH1 CH4 Adjust the value with CH5 and CH6 or press the same button CH1 CH4 for OFF or UNAFFECTED intensity or 1 tim...

Page 9: ...ated according to the load connected Attention If any cable is damaged it must be immediately replaced by a qualified person in order to avoid any hazard manufacturer reserves the right for changing t...

Page 10: ...TVDMMxxxG10S 400w TVDMMxxxG10SZ The connection cables must have a section suitable to the maximum load applied to the output and to the additional devices connected to the input Protection rating IP20...