2

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

 

DANGER

HOT GLASS 

WILL CAUSE 

BURNS. 

DO NOT TOUCH

 GLASS 

UNTIL COOLED. 

NEVER

 ALLOW CHILDREN 

TO TOUCH GLASS. 

A barrier designed to reduce the risk of burns from the 
hot viewing glass is provided with this appliance and shall 

be installed for the protection of children and other at-risk 

individuals.

CAUTION:

 Never connect heater directly to the Propane supply. This heater requires an external regulator (not 

supplied). Install the external regulator between the heater and Propane/LP supply. 
The installer must supply an external regulator. The external regulator will reduce the incoming gas pressure to 
between 11 and 14 inches of water. If you do not reduce incoming gas pressure heater regulator damage could 
occur. Install external regulator with the vent pointing down. Pointing the vent down protects it from freezing rain 
or sleet.

WARNING:  FIRE, EXPLOSION, AND ASPHYXIATION HAZARD

Improper installation, adjustment, alteration, service or maintenance can cause injury or 
property damage. Refer to this manual for correct installation and operational procedures. For 
assistance or additional information consult a qualified installer, service agency, or gas supplier. 

Read and follow instructions and precautions in User’s Information Manual provided with this 

heater.

WARNING:

 

THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS 

INCLUDING LEAD AND LEAD COMPOUNDS, WHICH ARE KNOWN TO 
THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR 
OTHER REPRODUCTIVE HARM. FOR MORE INFORMATION VISIT WWW.
P65WARNINGS.CA.GOV

WARNING: 

Fuels used in liquefied propane gas appliances, 

and the products of combustion of such fuel, can expose you to chemicals 
including benzene, which is known to the state of California to cause 
cancer and cause birth defects or other reproductive harm, for more 
information go to  www.P65Warnings.ca.gov

Due to high temperatures, heater should be 
kept out of traffic and away from furniture and 
draperies. 

Do not place clothing or other flammable material 
on or near the appliance.

Children and adults should be alerted to the 
hazard of high surface temperature and should 
stay away to avoid burns or clothing ignition.

Young children should be carefully supervised 
when they are in the same room with heater. 

A barrier designed to reduce the risk of burns 
from the hot viewing glass is provided with this 
appliance and shall be installed for the protection 

of children and other at-risk individuals.

If the barrier becomes damaged, the barrier shall 

be replaced with the manufacturer’s barrier for 

this appliance.

Any safety screen or guard removed for servicing 
an appliance must be replaced prior to operating 
the heater.

Installation and repair should be done by a 
qualified service person. The appliance should 
be inspected before use and at least annually 
by a professional service person. More frequent 
cleaning may be required due to excessive lint 
from carpeting, bedding material, etc. It is 
imperative that control compartments, burners, 
and circulating air passageways of the appliance 
be kept clean.

WARNING:

 

This 

appliance is equipped for propane 
gas. Field conversion is not 
permitted.

WARNING:

 

Do not use 

a blower insert, heat exchanger 
insert or other accessory not 
approved for use with this heater.

SOCIAL MEDIA

In order to provide the best service possible Mr. Heater is now giving you more ways to get in touch with us:

WEBSITE:   Mr. Heater’s full line of product are now at:

 www.mrheater.com

 FACEBOOK: Find us on Facebook 

 

 TWITTER: Find us on twitter 

 YouTube: There are now informational videos on Youtube.

Summary of Contents for MHVFBF10LP

Page 1: ... Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire ...

Page 2: ... you to chemicals including benzene which is known to the state of California to cause cancer and cause birth defects or other reproductive harm for more information go to www P65Warnings ca gov Due to high temperatures heater should be kept out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Children and adults should be ...

Page 3: ...ght until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapor...

Page 4: ...onal Fuel Gas Code or applicable local codes 3 Add the Btu hr of all the fuel burning appliances in the SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensor ODS safety shut off system The ODS pilot shuts off the heater if there is not enough fresh air IGNITION SYSTEM PIEZO The heater is equipped with a piezo manual ignitor This system requires no matches batteries or other source ...

Page 5: ...s Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all appliance in both spaces Ventilation from Outdoors If necessary provide extra fresh air by using ventilation grills or ducts Connect these it...

Page 6: ...or convenience and efficiency install the heater Where there is easy access for operation inspection and service In the coldest part of the room CAUTION If you install the heater in a home garage Heater pilot and burner must be at least 18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces ne...

Page 7: ...bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry Note Wall anchors mounting screws and spacer ar...

Page 8: ...ake gas connection CAUTION Never connect heater directly to the Propane supply This heater requires an external regulator not supplied Install the external regulator between the heater and Propane LP supply The installer must supply an external regulator The external regulator will reduce the incoming gas pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure heat...

Page 9: ... relieve pressure in supply piping system 7 Reconnect heater and equipment shutoff valve to gas supply 8 Reconnected fittings must be checked for leaks in next section Low Pressure Test Pressure Equal To or Less Than psig 3 5 kPa 1 The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at t...

Page 10: ...ontrol know slightly and turn counterclockwise to PILOT IGN and depress for five 5 seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This will allow air to bleed from the gas system 6 Push in control knob and rotate control knob back to OFF position then rotate counterclockwise to PILOT IGN position Thi...

Page 11: ...e to keep the primary air opening s of the burner s clean may result in sooting and property damage CLEANING ODS PILOT AND BURNER Use as vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly ...

Page 12: ...t shutoff valve not fully open Fully open equipment shutoff valve Thermocouple connection loose at control valve Hand tighten thermocouple nut until snug and then tighten 1 4 turn more Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following a Low gas Pressure b Dirty or Partially clogged ODS ...

Page 13: ...p using odor causing products while heater is running Gas leak See WARNING statement at top of page 12 Locate and correct all leaks see Checking Gas Connections page 9 Heater shuts off in use ODS operates Not enough fresh air is available Open window and or door for ventilation Low line pressure Contact local gas company ODS pilot is partially clogged Clean ODS pilot see Cleaning and Maintenance p...

Page 14: ...tor 1 10 80055 Regulator Mounting Bracket 1 ITEM P N PART DESCRIPTION QTY 1 1 80058 Floor Mounting Feet Beige 1 80214 Floor Mounting Feet White 1 12 NA Regulator Connection 1 13 80036 Wall Mounting Bracket 1 14 80052 Back Panel Beige 1 80177 Back Panel White 1 15 80005 Valve Bracket 1 16 80006 Knob 1 17 80080 LP Valve 1 18 80034 Glass Bracket 1 70342 Hardware Kit not shown 1 WARNING Failure to pos...

Page 15: ...ting Bracket 1 8 80058 Floor Mounting Feet Beige 1 ITEM P N PART DESCRIPTION QTY 80214 Floor Mounting Feet White 1 9 NA Regulator Connection 1 10 80036 Wall Mounting Bracket 1 1 1 80052 Back Panel Beige 1 80177 Back Panel White 1 12 80005 Valve Bracket 1 13 80006 Knob 1 14 80080 LP Valve 1 70342 Hardware Kit not shown 1 80009 01 Orifice not shown 1 WARNING Failure to position the parts in accordan...

Page 16: ...D BY A QUALIFIED SERVICE AGENCY REPLACEMENT PARTS ORDERING INFORMATION PURCHASING Accessories may be purchased at any Mr Heater local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 800 251 0001 www mrheater com Our office hours are 8 00 AM 5 00 PM EST Monday through Friday Please include the model number date of purchase serial number and description of p...