TROUBLESHOOTING INFORMATION: 
(Model MH18CH)

If burner lights, but goes out when button is released.

CHECK

Loose wires on tipover switch.

Loose lead wire at control valve and ODS/Pilot

 

Assembly.

Loose thermocouple and tighten if necessary.

Defective ODS/Pilot Assembly. Replace if necessary.

Defective control. Replace if necessary.

Defective tip over switch. Replace if necessary.

Tip-Over Switch Arrangement

NOTE: The purpose of the Tip-Over Switch is to stop the flow of 
gas  when heater is accidentally knocked over. When and if the 
heater is knocked over, simply stand heater up, wait 5 minutes 
and relight.

REPLACEMENT PARTS LIST

ITEM

NO.

PART 

NUMBER

DESCRIPTION

1

27510

PANEL, FRONT, MH18CH

2

27511

PANEL, TOP, MH18CH

3

27512

SHIELD, RADIATION, MH18CH

4

27513

KNOB, CONTROL, MH18CH

5

27514

CASTER, LOCKING, MH18CH

6

27515

ASSEMBLY, HOSE, REGULATOR

7

27516

VALVE, CONTROL, MH18CH

8

27517

GUARD, WIRE, MH18CH

9

27518

BRACKET, TANK, MOUNT, 

10

42116

SWITCH, TIPOVER, MH18CH

12

27524

SHIELD, HEAT, MH18CH

13

27520

BASE, METAL, MH18CH

14

27521

BASE, TANK, SUPPORT, MH18CH

15

27530

SCREW, HAND, BASE, MH18CH

16

27531

BRACKET, HOUSING, SUPPORT

17

27529

REFLECTOR, MH18CH

18

27528

GUARD, WIND, MH18CH

19

27522

BRACKET, ODS, MH18CH

20

27523

ODS, MH18CH

21

27526

*

ASSEMBLY, BURNER, MH18CH

22

27941

O-RING, ORIFICE

23

27527

ORIFICE, MH18CH

24

27525

BRACKET, VALVE, MOUNT

25

27532

HOLDER, ORIFICE, MH18CH

* Burner tiles not included. 

   

Order 27533 for complete assembly.

Summary of Contents for MH18CH

Page 1: ...INSTRUCTION MANUALS LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FRO...

Page 2: ...a MIN 5 psi 34 5 kPa MANIFOLD PRESSURE 11 W C VENTILATION WARNING THIS APPLIANCE IS UNVENTED AND MUST BE USED ONLY IN A WELL VENTILATED AREA The flow of combustion and ventilation air must not be obst...

Page 3: ...he nameplate B Each heater is equipped with a 100 safety shutoff push button valve which will automatically stop the flow of gas in the event the heater fails to operate for any reason A tip over swit...

Page 4: ...the base tank support 2 Align the Base Tank Support tabs 2 with the open slots 2 on the bottom of the heater along with aligning the bottom heater tabs 2 with the open slots 2 on the base tank suppor...

Page 5: ...gnite the appliance all gas fittings and connections must be thoroughly checked for gas leaks Apply a small amount of a mild soap and water solution to all fittings and connections and observe for esc...

Page 6: ...heater including hose and regulator assembly must be inspected before each use If the hose for Model MH18CH shows evidence of excessive abrasion or wear or if the hose is cut it must be replaced prior...

Page 7: ...tally knocked over When and if the heater is knocked over simply stand heater up wait 5 minutes and relight REPLACEMENT PARTS LIST ITEM NO PART NUMBER DESCRIPTION 1 27510 PANEL FRONT MH18CH 2 27511 PA...

Page 8: ...TTENDED WHILE BURNING Portable Propane Caninet Heater Model MH18CH IF SERVICE IS REQUIRED PLEASE DO NOT RETURN THIS APPLIANCE TO YOUR STORE For information regarding service please call our Toll Free...

Page 9: ...levels of CO CO2 and NO2 existing at the construction site at the minimum at the start of the shift and after 4 hours Provide ventilation air exchange either natural or mechanical as required to maint...

Page 10: ...semblies controls etc furnished by Enerco Group Inc will carry a one 1 year warranty on the applicable warranties of the suppliers The sole responsibility of Enerco Group Inc under this warranty shall...

Reviews: