tecHnical speciFicatiOns

MH 4000dF

Hs 4000dF

MH 6000dF

Hs 6000dF

Heat input

[kBTU/h]

400

610

Air flow

[cfm]

2.500

2.800

Fuel Type

Diesel/Kerosene/#1-2 Fuel Oil

Heat output

[kBTU/h]

-

-

Fuel consumption

[gal/h]

12.83

4.46

[lb/h]

19.58

30.84

Power supply

Phase

1

1

Voltage

[V]

120

120

Frequency

[Hz]

60

60

electric consumption

[W]

1,170

1,040

[A]

8.30

10.50

Nozzle

[USgal/h]

2.00-30° S

3.00-80°S

Pump pressure

[psi]

174

217

Max static pressure

[in WC]

-

-

Recommended max. temp. in the air 
duct

[°F]

-

-

Adjustment of combustion air flap

[in]

a=0.59

a=1.00

-

-

Flue diameter

[in]

-

-

Compulsory flue draft

[in WC]

-

-

Tank capacity

[gal]

27.7

35.7

Dimensions, l x W x H

[in]

62.4x27.6x39

67.9x27.6x41.2

Net Weight

[lb]

222

246

iMpOrtant

Before using the heater, read and understand all instructions and 
follow them carefully. The manufacturer is not responsible for 
damages to goods or persons due to improper use of units.

general recOMMendatiOns

The direct-fired heater runs on diesel fuel. This direct combustion 
heater exhausts hot air and the combustion products into 
the room, while those with indirect combustion are fitted 
with a flue to take the fumes away through the chimney.

  Always follow local ordinances and codes when using this 

heater:

•  Read and follow this owner’s manual before using the 

heater.

•  Use only in places free of flammable vapors or high dust 

content.

•  Never use heater in immediate proximity of flammable 

materials (the minimum distance must be 6 ft.).

•  Make sure fire fighting equipment is readily available.
•  Make sure sufficient fresh outside air is provided according 

to the heater requirements. Direct combustion heaters 
should only be used in well vented areas in order to avoid 
carbon monoxide poisoning.

•  Never block air inlet (rear) or air outlet (front).
•  In case of very low temperatures add kerosene to the 

heating oil.

•  Make sure heater is always under surveillance and keep 

children and animals away from it;

•  Before starting the heater always check free rotation of 

ventilator fan.

•  Unplug heater when not in use.

Summary of Contents for 3500DF

Page 1: ...44135 800 251 0001 DIRECT FIRED PORTABLE HEATER heatstar BY eNERCO mr heater If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal i...

Page 2: ...OW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING NOT FOR HOME OR RECREATION...

Page 3: ...proper use of units General Recommendations The direct fired heater runs on diesel fuel This direct combustion heater exhausts hot air and the combustion products into the room while those with indire...

Page 4: ...heater and it might be necessary to renew the starting procedure once or twice by depressing the reset button 1 Should the heater not start check that oil tank is full and depress reset button 1 Shou...

Page 5: ...free life to your heater Warning Never service heater while it is plugged in operating or hot Severe burns or electrical shock can occur Every 50 hours of operation disassemble filter and wash with cl...

Page 6: ...or cleanliness Replace H V transformer Flame control box defective Replace control box Photocell defective Clean or replace photocell Not enough or no fuel at all at burner Check state of motor pump p...

Page 7: ...gram 4000 and 6000 Series Models FU Fuse IT Transformer H V LI1 Overheat Thermostat EV1 Solenoid Valve 1 FO Photocell CO Condenser MV Fan Motor ST Electric pilot RV Control TA Room Thermostat RE Relay...

Page 8: ...ired Portable Heater 25 27 29 03 47 A 05 15 08 09 B 46 17 10 06 01 04 37 30 12 20 11 16 14 17 14 13 86 12 82 84 83 76 75 70 51 56 57 58 59 63 69 65 66 68 80 72 74 77 52 53 67 54 61 60 64 62 19 33 34 3...

Page 9: ...pport 50135 G02076 H T cables 90 COFI 17 50055 I40329 tube BP 1 4 FF L 260mm 79 50323 E50328 photo cell 18 50056 I20176 9005 handle 50324 T20443 1 pump Danfoss BFA01 R4 19 50057 C30319 plug 50139 T204...

Page 10: ...paid within said one year period and found by the Company to have imperfections in material or workmanship If a part is damaged or missing call our Technical Support Department at 800 251 0001 Address...

Reviews: