background image

Operating instructiOns and Owner’s Manual

read instructiOns careFullY:

 Read 

and follow all instructions. Place instructions in 
a safe place for future reference. Do not allow 
anyone who has not read these instructions to 
assemble, light, adjust or operate the heater.

Mo
D

el

Mo
D

el

4000DF 6000DF

4000DF 6000DF

07/08  #50125

ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001

direct Fired 

pOrtaBle Heater

Heatstar

BY enercO

Mr. Heater

if the information in this manual is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or loss of life.

warning:

 —  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 

other appliance.

—  Service must be performed by a qualified service agency.

This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate 
combustion and ventilation air must be provided. Refer to page 5.

Summary of Contents for 3500DF

Page 1: ...44135 800 251 0001 DIRECT FIRED PORTABLE HEATER heatstar BY eNERCO mr heater If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal i...

Page 2: ...OW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING NOT FOR HOME OR RECREATION...

Page 3: ...proper use of units General Recommendations The direct fired heater runs on diesel fuel This direct combustion heater exhausts hot air and the combustion products into the room while those with indire...

Page 4: ...heater and it might be necessary to renew the starting procedure once or twice by depressing the reset button 1 Should the heater not start check that oil tank is full and depress reset button 1 Shou...

Page 5: ...free life to your heater Warning Never service heater while it is plugged in operating or hot Severe burns or electrical shock can occur Every 50 hours of operation disassemble filter and wash with cl...

Page 6: ...or cleanliness Replace H V transformer Flame control box defective Replace control box Photocell defective Clean or replace photocell Not enough or no fuel at all at burner Check state of motor pump p...

Page 7: ...gram 4000 and 6000 Series Models FU Fuse IT Transformer H V LI1 Overheat Thermostat EV1 Solenoid Valve 1 FO Photocell CO Condenser MV Fan Motor ST Electric pilot RV Control TA Room Thermostat RE Relay...

Page 8: ...ired Portable Heater 25 27 29 03 47 A 05 15 08 09 B 46 17 10 06 01 04 37 30 12 20 11 16 14 17 14 13 86 12 82 84 83 76 75 70 51 56 57 58 59 63 69 65 66 68 80 72 74 77 52 53 67 54 61 60 64 62 19 33 34 3...

Page 9: ...pport 50135 G02076 H T cables 90 COFI 17 50055 I40329 tube BP 1 4 FF L 260mm 79 50323 E50328 photo cell 18 50056 I20176 9005 handle 50324 T20443 1 pump Danfoss BFA01 R4 19 50057 C30319 plug 50139 T204...

Page 10: ...paid within said one year period and found by the Company to have imperfections in material or workmanship If a part is damaged or missing call our Technical Support Department at 800 251 0001 Address...

Reviews: