750kW Containerized
Diesel Generator Set
Derating (60Hz)
The engine may be operated up to 5000 ft.
altitude and 95
o
F ambient temperature at the
Standby rating, wi thout derating. For
operation at higher altitudes and ambient
temperatures, the power should be derated
according to the following factors:
Altitude
Ambient
Temperature
Above 5000ft.
derate at 4%
per 1000 ft.
Above 95°F
derate at 1%
per 10°F
Inteligen Digital Genset Controller
■
Large graphic back-lit LCD display 128x64 pixel resolution
■
Automatic and manual starting and stopping
■
Phase sequence supervision
■
Automatic shutdown/alarm function
■
Input frequency 50-60 Hz
■
Parameters adjustable via PC or iG keyboard
■
Predefined and user definable configurations available.
One configuration includes set of inputs/outputs and parameters
■
Adjustable parameters for each configuration
■
6 LED indicators
■
Push buttons for simple control
■
4 programmable outputs (out of 20 functions selection)
■
4 binary configuration inputs
■
Lamp test during start up
■
Real time clock
■
Sealed membrane panel to IP65
■
180 x 113 mm front panel mounted case
■
Speed measurement from magnetic pickup
■
Oil pressure, Coolant temperature, Battery voltage and Fuel level
measurements
■
Running Hour Meter
■
All Generator metering, kVAr, kW, V1-V3, Hz, I1-I3, kWh, kVAh
■
Generator under/over voltage alarm/shutdown
■
Generator under/over frequency alarm/shutdown
■
Over Current alarm/shutdown
■
Warm up and cooling functions
■
Pre-lubrication function with timers
■
Adjustable crank attempts
■
Data logging
■
Remote communications (RS232/Modbus)
Digital Controller Features
Fuel System
Recommended Fuel
ASTM-D975-No.1 or No. 2-D
Filter Micron Size - 98% Efficiency
2
Total Fuel Flow
99 gal./hr. (374.7 L/Hr.)
Fuel Consumption
Diesel Fuel @ % of Load
gal/hr
L/hr
25%
16.0
61
50%
26.2
99
75%
40.5
153
100%
54.7
207
Cooling System
Exhaust Manifold Type
Dry
Radiator Design
Standard horizontal discharge
Coolant Capacity - Engine and Radiator
53 gal. (201 L)
Water Pump Design/Type
Belt Driven, Centrifugal
Coolant Flow
235 gal/min (889.5 L)
Heat Rejection to Coolant (Standby)
27860 BTU/min (29.5 kW)
Fan Horsepower
42.7 hp (32.0 kW)
Exhaust System
Standby
Prime
Exhaust Temperature at Rated kW
895
o
F
(479.4
o
C)
850
o
F
(454.4
o
C)
Exhaust Flow at Rated kW
6160 cfm
(174.3 m
3
/min)
5546 cfm
(157 m
3
/min)
Silencer Type
Critical
Maximum Allowable Backpressure
41 in/wc (10.2 kPa)
Exhaust Outlet Size at hook-up
2 x 8 in.