DEF TANK REPLENISHMENT SYSTEM • OPERATION MANUAL — REV. #0 (09/11/20) — PAGE 19
FAILURE MODES, EXTERNAL FAULTS ON
POWER DRIVERS
The tables shown below and on the preceding page contain
information about the actions taken by the IQAN-MC42FS
when certain failure-causing conditions occur. Failure
modes for internal faults are included in the total PFHd for
the module.
Expected channel status
a
Output pin
configuration
Failure mode
Start up
On
Off
Comment
Current out
Broken wire
open
load
open
load
Short to GND
(HS)
critical
error
overload
overload
Short to GND
(LS)
critical
error
overload
overload
SCG while off: coil is
energized for
50 ms before
detection
Short to Battery
(HS)
(no
contact)
open
load
-
Prevents module startup =>
LED showing Stopped,
Critical
Short to Battery
(LS)
(no
contact)
overload
-
Prevents module startup =>
LED showing Stopped,
Critical
Short LS+ to
LS-
overload
-
a
/
n
d
a
o
lr
e
v
o
d
a
o
lr
e
v
O
Insufficient
voltage on +BAT
saturated
n/a
Insufficient
voltage on
+BAT, current
saturated < 70%
open
load
n/a
PWM out
HS+LS
Broken wire
open
load
open
load
Short to GND
(HS)
critical
error
overload
overload
Short to GND
(LS)
critical
error
overload
overload
SCG while off: coil is
energized for
50 ms before
detection
Short to Battery
(HS)
(no
contact)
-
-
Prevents module startup =>
LED showing Stopped,
Critical
Short to Battery
(LS)
(no
contact)
overload
-
Prevents module startup =>
LED showing Stopped,
Critical
a
/
n
d
a
o
lr
e
v
o
d
a
o
lr
e
v
O
FAULT/ERROR CODES